EN
‐
13
Intended
use
FiltoSmart
100/200/300
,
referred
to as "unit",
may
only
be
used
as
specified
in
the
following:
•
Water
filtering
and
recirculation.
•
For
operation
with
freshwater
or
saltwater.
•
Operation
under
observance
of
the
technical
data.
The
following
restrictions
apply
to
the
unit:
•
Only
use
indoors
and
for
aquaristic
purposes
in
the
home
(not
for
commercial
use).
•
Only
operate
with
water
at
a
water
temperature
of
+4
°C
to
+35
°C.
Function
description
C
Drawn
in
by
a
pump
in
the
unit
head,
the
water
flows
through
two
filter
chambers
arranged
next
to
each
other.
Then
the
water
flows
back
into
the
aquarium
via
the
flow
‐
out
pipe
or
water
distributor.
Foam
filters
with
different
pore
densities,
and
acti
‐
vated
carbon/ceramic
substrate
serve
as
filter
media.
ACCESSING
THE
UNIT
Removing
the
connection
unit
How
to
proceed:
D
1. Turn
the
bayonet
closure
in
the
direction
"UN
‐
LOCK".
2.
Remove
the
connection
unit.
Fitting
the
connection
unit
How
to
proceed:
E
1. Fit
the
connection
unit.
–
Ensure
that
the
ridges
on
the
connection
unit
are
correctly
aligned
to
the
recesses
on
the
unit
head.
2. Turn
the
bayonet
closure
in
the
direction
"LOCK".
Dismantling
the
unit
head
It
has
to
be
removed
for
cleaning
and
maintenance
and
for
changing
the
filter
media.
Prerequisite:
•
The
connection
unit
has
been
removed.
(
→
Remo
‐
ving
the
connection
unit)
How
to
proceed:
F
1. Undo
the
fasteners.
2. Remove
the
unit
head.
Fitting
the
unit
head
How
to
proceed:
G
1.
Check
that
the
seal
on
the
unit
head
is
correctly
po
‐
sitioned.
–
Clean
the
seal,
replace
it
if
damaged.
2.
Ensure
that
the
vent
hose
is
in
place
and
is
pointing
upwards.
3.
Fit
the
unit
head
onto
the
container.
4.
Hinge
all
fasteners
up
and
lock
them
in
place.
INSTALLATION
AND
CONNECTION
Order
of
tasks
to
be
carried
out:
1. If
the
unit
is
to
be
installed
in
a
standing
position:
Fit
the
enclosed
rubber
feet
onto
the
base
of
the
con
‐
tainer.
2.
Position
the
filter
media
(
→
Cleaning/replacing
the
filter
media)
3.
Install
the
unit.
–
Install
the
unit
next
to
or
under
the
aquarium.
Note
the
maximum
head
height.
(
→
Technical
data)
4.
Establish
the
connections
(
→
Establishing
the
con
‐
nections)
Ensure
adequate
stability
H
To
increase
stability,
the
container
is
fitted
in
a
stand
(removable).
Screw
the
enclosed
rubber
feet
into
the
stand.
Only
install
the
container
with
the
stand
fitted.
Establishing
the
connections
Assembling
the
suction
unit
How
to
proceed:
I
Assemble
the
suction
unit.
Set
the
flow
rate.
–
Use
a
coin
to
turn
the
flow
regulator
in
the
hose
adapter
in
the
direction
of
MIN
or
MAX.
Assembling
the
flow
‐
out
unit
How
to
proceed:
J
Assemble
the
flow
‐
out
unit.
–
The
water
distributor
can
be
used
instead
of
the
flow
‐
out
pipe.
Use
a
coin
to
turn
the
flow
regulator
in
the
hose
adapter
to
MAX.
Summary of Contents for FiltoSmart 100
Page 3: ...3 C FST0004...
Page 4: ...4 FiltoSmart 100 200 300 D 1 2 E 1 2 FST0008 FST0012 F 2 1 1 FST0009...
Page 5: ...5 G 3 1 4 4 2 1 FST0010 H FST0006...
Page 6: ...6 FiltoSmart 100 200 300 I FSt0015...
Page 7: ...7 J FiltoSmart 300 FiltoSmart 100 200 FST0016...
Page 8: ...8 FiltoSmart 100 200 300 K 2 3 4 OUT IN 2 3 4 1 FST0017...
Page 10: ...10 FiltoSmart 100 200 300 O 100 200 300 1 2 FST0018...
Page 31: ......