Commissioning/start-up
► Thoroughly clean the pond before starting up the filter system for the first time to ensure that the filter
system is not overloaded by excessively soiled water. OASE recommends using the PondoVac pond
vacuum cleaner for cleaning the pond.
– This cleaning measure is normally not necessary for newly installed ponds.
► It is necessary to operate the filter system for 24 hours a day during the pond season.
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
► Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
► Isolate the device (disconnect from the power supply) before carrying out any work on it.
N O T E
A dimmer or timer will destroy the device.
► Only connect the device to a power supply without dimmer.
► Do not use a timer.
N O T E
Never allow the rinsing pump to run dry. Possible consequences: The rinsing pump will be destroyed.
► Check the water level at regular intervals. Ensure that the rinsing pump is always under water during
operation.
► Do not switch on the control system until the container is flooded with water.
5.1
Order of starting up steps
How to proceed:
A
1. Close the slide valve for the dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Remove the container cover.
4. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
5. Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing pump).
6. Fit the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted.
7. Switch on the control system and perform any necessary adjustments. (
→
Operation)
8. Switch on the filter pump and UVC clarifier (if applicable).
– Ensure that the water is returned to the pond via the return pipe.
9. Check all pipes, hoses and their connections for leaks.
– Expansion seals may leak initially until they have fully expanded on contact with water.
N O T E
New filters take approx. 3 to 4 weeks before the bacteria in the unit are fully established. During this time
– or at a water temperature of <10 °C – the filter may overflow. In this case the filter does not need to be
cleaned.
► When using filter starter, medicines or pond water treatments, leave the UVC clarifying unit switched
off for at least 36 hours so as not to impair their efficacy.
Summary of Contents for BioTec Premium 80000 EGC
Page 2: ...2 A BTC0089...
Page 3: ...3 B BTC0032...
Page 4: ...4 C BTC0091 D BTC0027...
Page 5: ...5 E F BTC0022 BTC0019 G ProfiClear0040 H FMR0031...
Page 6: ...6 I EGC0003 J ProfiClear0047 K L BTC0031 BTC0026...
Page 7: ...7 M BTC0090 N BTC0020...
Page 8: ...8 O BTC0021 P BTC0025...
Page 9: ...9 Q BTC0028 R BTC0029 S T BTC0023 BTC0024...
Page 290: ...RU 290 RU 8 30 12 30...
Page 293: ...RU 293 1 OASE Living Water BioTec Premium 80000 EGC 1 1 1 1 1 1 1 2 2 2 1...
Page 294: ...RU 294 2 2 ICD 20 2 3 3 3 1 BioTec Premium 80000 EGC 4 C 35 C...
Page 297: ...RU 297 4 B 4 1 UAC 12 oder UDC 30 UAC 12 UDC 30 2 UAC 12 UDC 30 2 25...
Page 301: ...RU 301 5 OASE PondoVac 24 5 1 A 1 2 3 4 5 6 7 8 9...
Page 302: ...RU 302 3 4 10 C 36 5 2 1 9000 2 9000 K 1 2 5 3 Er77 Er77 12 E7 Er77 Er77...
Page 303: ...RU 303 M 1 Er11 2 3 4 5 6 5 12500 4 100 3 1 75 2 50 1 25 1...
Page 308: ...RU 308 6 8 4 Er11 Er22 12 C 24 5 24 Er33 20 5...
Page 309: ...RU 309 Er44 3 5 OASE 27872 5 Er55 960 48 5 960 Er66 Er77...
Page 311: ...RU 311 N 5 20 8 250 OASE Biokick 2 1...
Page 312: ...RU 312 8 8 1 PumpClean OASE 8 2 DN 75 10 8 3 100 10 N 1 5 6 2 DN 75...
Page 313: ...RU 313 3 DN 75 4 5 25 8 4 DN 75 O 1 2 3 4 5 6 7 8 8 5 L 1 2 3...
Page 315: ...RU 315 R 1 2 8 8 S 1 2 8 9 T 1 2 3 4...
Page 316: ...RU 316 9 4 C 20 10 C 4 C 8 10 OASE 11 OASE www oase livingwater com zapasnyechasti di 12...
Page 319: ...319...
Page 320: ...54882 10 17...