- EN -
61
8.4
Replacing foam filters
Prerequisite
► The filter pump is switched off.
► All other electrical units of the filter system are switched off (e.g. UVC clarifier).
► The foam filters are cleaned. (
→
Cleaning the foam filters)
► Open the slide valve for the DN 75 dirt outlet at the bottom of the container and dispose of the soiled
water in a permissible way.
How to proceed:
O
1. Release the the bayonet closure in the inner cover by turning it counter-clockwise (looking down onto
the bayonet ring).
2. Press the retaining clamps on both sides and remove the inner cover together with foam holders from
the container.
– Recommendation: First unlock the inner cover on one side and lift up slightly, then unlock the other
side.
– If the inner cover is too heavy, release the foam holders, allowing them to lower into the container,
before lifting out the inner cover.
3. Pull the foam holders up slightly, press both engagement hooks on the foam holders together and
push them down and out of the inner cover.
4. Press in the four engagement hooks on the top foam part and take out the foam holders together with
the filter cartridge.
– Recommendation: Press each pair of opposing engagement hooks together one after the other
and push them down and out of the inner cover.
5. Remove the used filter cartridge and bottom foam part from the foam holder.
– Correctly dispose of the filter cartridges in accordance with the regulations.
6. First fit the bottom foam part then the new filter cartridge onto the foam holder.
– Ensure that the filter cartridge fits exactly into the bottom foam part.
7. Insert the foam holder with the new filter cartridge into the inner cover from below, pulling the foam
holder up until the engagement hooks engage in the inner cover.
– Perfect seating of the filter cartridge is only guaranteed when all engagement hooks are engaged.
8. Turn the bayonet closure in the inner cover clockwise to fasten.
8.5
Cleaning the rinsing device
How to proceed:
L
1. Start a manual cleaning cycle to check that the rinsing nozzle is functioning perfectly. (→ Manual
2. Loosen the union nut on a clogged nozzle, remove the nozzle and seal from the rinsing pipe and clean
the parts.
3. Push the union nut onto the nozzle and screw it together with the seal onto the rinsing pipe.
– Align the nozzle so that the marking is at the top.
– Hand-tighten the union nut.
Summary of Contents for BioTec Premium 80000 EGC
Page 2: ...2 A BTC0089...
Page 3: ...3 B BTC0032...
Page 4: ...4 C BTC0091 D BTC0027...
Page 5: ...5 E F BTC0022 BTC0019 G ProfiClear0040 H FMR0031...
Page 6: ...6 I EGC0003 J ProfiClear0047 K L BTC0031 BTC0026...
Page 7: ...7 M BTC0090 N BTC0020...
Page 8: ...8 O BTC0021 P BTC0025...
Page 9: ...9 Q BTC0028 R BTC0029 S T BTC0023 BTC0024...
Page 290: ...RU 290 RU 8 30 12 30...
Page 293: ...RU 293 1 OASE Living Water BioTec Premium 80000 EGC 1 1 1 1 1 1 1 2 2 2 1...
Page 294: ...RU 294 2 2 ICD 20 2 3 3 3 1 BioTec Premium 80000 EGC 4 C 35 C...
Page 297: ...RU 297 4 B 4 1 UAC 12 oder UDC 30 UAC 12 UDC 30 2 UAC 12 UDC 30 2 25...
Page 301: ...RU 301 5 OASE PondoVac 24 5 1 A 1 2 3 4 5 6 7 8 9...
Page 302: ...RU 302 3 4 10 C 36 5 2 1 9000 2 9000 K 1 2 5 3 Er77 Er77 12 E7 Er77 Er77...
Page 303: ...RU 303 M 1 Er11 2 3 4 5 6 5 12500 4 100 3 1 75 2 50 1 25 1...
Page 308: ...RU 308 6 8 4 Er11 Er22 12 C 24 5 24 Er33 20 5...
Page 309: ...RU 309 Er44 3 5 OASE 27872 5 Er55 960 48 5 960 Er66 Er77...
Page 311: ...RU 311 N 5 20 8 250 OASE Biokick 2 1...
Page 312: ...RU 312 8 8 1 PumpClean OASE 8 2 DN 75 10 8 3 100 10 N 1 5 6 2 DN 75...
Page 313: ...RU 313 3 DN 75 4 5 25 8 4 DN 75 O 1 2 3 4 5 6 7 8 8 5 L 1 2 3...
Page 315: ...RU 315 R 1 2 8 8 S 1 2 8 9 T 1 2 3 4...
Page 316: ...RU 316 9 4 C 20 10 C 4 C 8 10 OASE 11 OASE www oase livingwater com zapasnyechasti di 12...
Page 319: ...319...
Page 320: ...54882 10 17...