Installation 

 

 

Attention! Dangerous electrical voltage. 
Possible consequences:

 Death or severe injury. 

Protective measures:

 

  Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: 

Isolate the units and installations (switch off and disconnect from the power supply) before reaching into 
the water. 

  Isolate the unit before starting any work. 

  Secure the unit to prevent unintentional switching on. 

 
 

 A 

Oase recommends hoses suitable for a minimum pressure of 7.2 psi (0.5 bar). 
Cut the stepped hose adapters such that the connection opening coincides with the hose diameter. This helps avoid 
pressure loss. 
Ensure that the unit is placed at a flood protected place and on firm ground. Keep a minimum distance from the pond 
edge of 6.6 ft (2 m). Ensure unrestricted access to the cover to be able to carry out work on the unit. (A1) 
Push or turn the hose onto the stepped hose adapter, secure with the hose clip, then screw the stepped hose adapter 
on the water inlet (A2). 
Ensure that the drain pipes for the water return (A4) are laid towards the pond with a suitable incline (>1 %). Oase rec-
ommends to return the clean water into the pond via a water course to additionally enrich the water with oxygen.  
An optional adapter set is available for the cleaning outlet (A3). For this purpose, remove the cover cap from the clean-
ing outlet. Push the union nut over the hose, slide the stepped hose adapter without thread onto the hose end and se-
cure with the hose clip. Connect the stepped hose adapter with union nut and flat seal to the cleaning outlet. Push the 
stepped hose adapter with thread onto the other hose end, secure with the hose clip and screw on the cover cap in-
cluding flat seal. Lay the hose with a suitable incline (>1 %) towards the sewage system or to a flower bed. 

 

Start-up 

 

 

 

Attention!

 Never operate the unit with a water pressure of more than 2.9 psi (0.2 bar)! 

 

 

 

Attention!

 Never operate the unit without water or without a pump filter! 

 

 

 

Note! 

For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into 
the casing. 

 

 B 

This is how to connect the power supply: 

Switching on:

 Connect the unit to the mains. The unit switches on as soon as the power connection is established. 

Switching off:

 Disconnect the unit from the mains. 

Check the correct seating of hoses and cover cap prior to starting up. Never operate the UVC clarifying unit without 
water. 
Switch on the pump and wait until the filter housing is filled with water. Check all connections for leaks. 
Connect the power plug of the UVC clarifying unit, the blue control lamp is lit (B). In the event of overheating, the tem-
perature monitor switches the UVC clarifying unit off automatically, the UCF clarifying unit automatically switches on 
again once it has cooled down. 

Note:

 After a new installation, the unit only reaches its full biological cleaning effect after a few weeks. The full effect 

on bacteria is only reached as from a water temperature of 50 °F (+ 10 °C). 

40378-09-14_GA_BioSmart 1600_USA6   6

18.09.2014   11:34:09

Summary of Contents for BioSmart 1600

Page 1: ...40378 09 14 BioSmart 1600 Operating instructions Instrucciones de uso Notice d emploi 40378_GA_BioSmart_1600_USA_A5_end_ 16 09 14 15 22 Seite 2...

Page 2: ...2 A BST0011 B BST0002 40378 09 14_GA_BioSmart 1600_USA2 2 18 09 2014 11 34 06...

Page 3: ...3 C BST0003 40378 09 14_GA_BioSmart 1600_USA3 3 18 09 2014 11 34 07...

Page 4: ...4 D BST0004 40378 09 14_GA_BioSmart 1600_USA4 4 18 09 2014 11 34 08...

Page 5: ...anger which can lead to death or severe injuries if the appropriate measures are not taken Important information for trouble free operation Intended use BioSmart 1600 referred to in the following as u...

Page 6: ...dapter without thread onto the hose end and se cure with the hose clip Connect the stepped hose adapter with union nut and flat seal to the cleaning outlet Push the stepped hose adapter with thread on...

Page 7: ...rs C5 Remove the foam filters from the holders and clean with clear water Open the cover cap at the cleaning outlet and clean filter housing inner lid and cover with water Reassemble the filter in the...

Page 8: ...e Remedy The unit performance is not satisfactory Unit has been in operation only for a short time The complete biological cleaning effect is only achieved after several weeks Water extremely soiled R...

Page 9: ...puede provocar la muerte o graves lesiones si no se toman las me didas correspondientes Indicaci n importante para un funcionamiento sin fallos Uso conforme a lo prescrito BioSmart 1600en lo sucesivo...

Page 10: ...la boquilla con la abrazadera de tubo flexible Conecte la boquilla portatubo escalonada con tuerca racor y junta plana en la salida de limpieza Desplace la boquilla portatubo escalonada al otro extre...

Page 11: ...limpie la carcasa del filtro la tapa interior y la tapa con agua Monte el filtro en secuencia contraria Disponga los elementos de espuma filtrantes en el sentido que fluye el agua primero los elemento...

Page 12: ...po no est todav a largo tiempo en servicio El pleno efecto de limpieza biol gico se alcanza despu s de algunas semanas Agua extremadamente sucia Elimine las algas y hojas del estanque Cambie el agua E...

Page 13: ...des blessures graves si les mesures correspondantes ne sont pas prises Consigne importante pour un fonctionnement exempt de d rangement Utilisation conforme la finalit BioSmart 1600 appel par la suite...

Page 14: ...en d un collier de serrage Raccorder l embout tages avec l crou raccord et le joint plat sur l vacuation de nettoyage Glisser l embout tages avec filetage sur l autre extr mit du tuyau le fixer au moy...

Page 15: ...nettoyer l eau le carter du filtre le couvercle int rieur et le couvercle Remonter le filtre dans l ordre inverse Placer les mousses filtrantes dans le sens d coulement de l eau tout d abord les mous...

Page 16: ...ervice que depuis peu de temps L effet de nettoyage biologique complet n est atteint qu apr s quelques semaines L eau est extr mement sale Retirer les algues et les feuilles du bassin rem placer l eau...

Page 17: ...ures below zero centigrade Operate the UVC clarifying unit at a maximum pres sure of 2 9 psi 0 2 bar Do not dispose of together with household waste Attention Read the operating in structions FR Prote...

Page 18: ...18 BST0010 40378 09 14_GA_BioSmart 1600_USA18 18 18 09 2014 11 34 09...

Page 19: ...40378 09 14_GA_BioSmart 1600_USA19 19 18 09 2014 11 34 10...

Page 20: ...OASE North America Inc www oase livingwater com 40378 09 14 40378 09 14_GA_BioSmart 1600_USA20 20 18 09 2014 11 34 10...

Reviews: