Storage/Over-wintering
•
Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures
are to be expected.
•
Drain and thoroughly clean the unit, check for damage.
•
Remove, clean, dry and store all filters in a frost-free environment.
•
Ensure that the storage place is inaccessible to children.
•
Cover the filter container such that the ingress of rain water is excluded.
•
Drain all hoses, pipes and connections as far as possible.
Wear parts
The UVC lamp, the quartz glass and the foam filters are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
Malfunction Cause
Remedy
The unit performance is not satisfactory
Unit has been in operation only for a short time
The complete biological cleaning effect is only
achieved after several weeks
Water extremely soiled
Remove algae and leaves from the pond, per-
form a partial water change
Excessive fish and animal population
Guide value: approx. 2 ft (60 cm) fish length in
265 gal (1 m³) pond water
Foam filters soiled
Clean filters
Pump filter housing soiled
Clean pump filter housing
Impeller unit blocked
Clean pump
Quartz glass tube soiled
Remove UVC and clean quartz glass
UVC lamp capacity exhausted
Replace the lamp after approx. 8000 operating
hours
UVC lamp display is not lit
Power supply of UVC not connected
Connect UVC power plug
UVC lamp defective
Replacing the UVC lamp
Connection defective
Check electrical connection
UVC overheated
UVC automatically switches on when cooled
down
No water outlet from the pond inlet
Pump power supply not connected
Connect pump power supply
Pond inlet blocked
Clean pond inlet
40378-09-14_GA_BioSmart 1600_USA8 8
18.09.2014 11:34:09
Summary of Contents for BioSmart 1600
Page 2: ...2 A BST0011 B BST0002 40378 09 14_GA_BioSmart 1600_USA2 2 18 09 2014 11 34 06...
Page 3: ...3 C BST0003 40378 09 14_GA_BioSmart 1600_USA3 3 18 09 2014 11 34 07...
Page 4: ...4 D BST0004 40378 09 14_GA_BioSmart 1600_USA4 4 18 09 2014 11 34 08...
Page 18: ...18 BST0010 40378 09 14_GA_BioSmart 1600_USA18 18 18 09 2014 11 34 09...
Page 19: ...40378 09 14_GA_BioSmart 1600_USA19 19 18 09 2014 11 34 10...