Product Description 

 

 B 

Aquarius Eco Expert 22000/28000

 

Pump casing 

  The position of the outlet can be changed by fitting the pump casing rotated through 90°. 

Outlet (pressure socket) 

Inlet (suction socket) 

Filter housing 

Stand 

  Ensures secure and stable positioning of the pump. 

  Can be firmly bolted to the ground. 

Connection OASE Easy Garden Control (EGC) 

  The pump can be controlled via EGC with Eco Control or InScenio FM-Master WLAN (optional). 

  This manual does not contain a description of the connection and operation of EGC. For information please contact your specialist dealer 

or OASE. 

 

Important

: Moisture at the connections can damage the pump. 

  Only remove the protection caps for connecting the EGC lines. 

  Ensure that the rubber seals are clean and fit exactly. 

  Replace damaged rubber seals. 

Switch for switching on/switching off the Dynamic Function 

 

 

 

 

Properties 

 

  Excellent delivery rates meeting the requirements of demanding filter systems and large water courses and waterfalls. 

  Can deal with coarse debris with a particle size of up to 4 mm. 

  Ergonomic handle for safe transport.  

  Suitable for immersed or dry installation. 

  Unique, patented frost protection: The pump is guaranteed to operate without damage at temperatures as low as  

-20 °C. 

  Suitable for swimming ponds and natural swimming pools (installed in an external pump chamber).  

 

 

 

Dynamic Function 

 

Different values for the pump flow rates are pre-programmed in the pump control system to allow a dynamic fountain 
pattern with changing heights and diameters. When the Dynamic Function is activated, the pump is continuously con-
trolled with these values. 

 

 

 

Intended use 

 

Aquarius Eco Expert 22000/28000, referred to as "unit", may only be used as specified in the following: 

 

  Pumping of normal water for creating fountains. 

 

  Operate in accordance with instructions.  

 

  Operation under observance of the permissible water quality. (

 Water quality) 

 

 

 

The following restrictions apply to the unit: 

 

  Do not use in swimming ponds. 

 

  Never use the unit to convey fluids other than water. 

 

  Never run the unit without water. 

 

  Do not use for commercial or industrial purposes. 

 

  Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances. 

 

  Do not connect to the domestic water supply. 

 

 

 

Summary of Contents for Aquarius Eco Expert 28000

Page 1: ...42423 09 16 MH Aquarius Eco Expert 22000 28000 42423 GA Aquarius_Eco_Expert_end_ 13 09 16 16 48 Seite 2...

Page 2: ...2 A B ARS0033 ARS0034 C ARS0025 D ARS0026...

Page 3: ...3 E ARS0027 F ARS0030...

Page 4: ...4 G ARS0029 H ARS0028...

Page 5: ...5 I ARS0031...

Page 6: ...disconnect all units in the water that have a voltage of 12 V AC or 30 V DC from the power supply Only operate the unit if no persons are in the water Do not use the unit if electrical cables or housi...

Page 7: ...carried out in accordance with these instructions Adhere to the safety information for the correct and safe use of the unit Keep these instructions in a safe place Please also hand over the instructi...

Page 8: ...ris with a particle size of up to 4 mm Ergonomic handle for safe transport Suitable for immersed or dry installation Unique patented frost protection The pump is guaranteed to operate without damage a...

Page 9: ...pond to avoid excessively soiled water from being drawn into the pump How to proceed E 1 Screw the stepped hose adapter including union nut and sealing ring to the outlet 2 Slip the hose clip over the...

Page 10: ...Control is limited The unit is not protected from running dry Remedy of faults Malfunction Cause Remedy Pump does not start No mains voltage Check the mains voltage Check supply lines Pump does not de...

Page 11: ...basket and remove the filter basket 2 Clean all parts Use a soft brush Rinse parts in clean water 3 Reassemble the unit in the reverse order Replacing the impeller unit N O T E The impeller unit is gu...

Page 12: ...thoroughly with a soft brush and water check it for damage then store immersed in water or filled with water Do not immerse the power plug in water Repair Repair is not possible in the following cases...

Page 13: ...ffektopptak Kapasitet Vanns yle Nedsenkningsdybde SV Typ Anslutningssp nning Effekt Matningsprestanda Vattenpelare Doppningsdjup FI Tyyppi Verkkoj nnite Ottoteho Sy tt teho Vesipylv s Upotussyvyys HU...

Page 14: ...aks omgivelsestemperatur ved tvangskj ling Kabellengde M l Vekt SV Typ Installation p torr plats Max omgivningstemperatur vid naturlig konvektion Installation p torr plats Max omgivningstemperatur vid...

Page 15: ...tt ned til 4 m dyp Beskytt mot direkte sollys Ikke kast i alminnelig husholdningsavfall NB Les bruksanvisningen SV Dammt t Vattent t till 4 m djup Skydda mot direkt solstr lning F r inte kastas i hush...

Page 16: ...ur SV Rekommenderade vattenv r den ph v rde Total h rdhet Fritt klor Kloridhalt Salthalt Temperatur FI Suositellut vesiarvot ph arvo Kokonaiskovuus Vapaa kloori Kloridipitoisuus Suolapitoisuus L mp ti...

Page 17: ...42423 10 17...

Reviews: