background image

4

INST

ALLA

TION

INSTALLATION

INSTALLATION

• Leveling Instructions

The

C

elesta 

G

emini

comes completely assembled and ready to use. Plug the

cord into a functioning outlet that is rated for the table.

Arrange the power cord and control cords so that they will not create a tripping
hazard. Place the controls in a safe location where they are convenient and
accessible. Keep the controls out of the way of all table mechanisms.

L E V E L I N G   I N S T R U C T I O N S :

If Table Will Not Sit Flat on the Floor:

The 

C

elesta 

G

emini

is equipped with Leveler Feet that adjust to level 

the table on uneven floors. To adjust the Leveler Feet to suit common
floor differences you will need to use a 

1

/

2

" open-end wrench or an

adjustable wrench. Adjust each leg individually in turn by adjusting the
height of each leveler foot until the unit rests level and steady. This
adjustment will not effect the function of the table.

1/2" Open-end Wrench

Leveler Foot

CAUTION

The table weighs as much 
as 300 lbs. 

DO NOT

lift or

move the unit without using
proper safely procedures 
or equipment. 

DO NOT

turn

the 

C

elesta 

G

emini

™ 

on its side

for any reason. To do so
could cause damage to the
base and 

will

void the warran-

ty. There are no serviceable
items that require this action.
Never lift the table by grasp-
ing the table top as the
table top is not designed to
hold the weight of the base
and you could damage the
table.

IMPORTANT

• Leveling Feet

When operating the 

C

elesta 

G

emini

™ 

controls be 

sure to observe all cautions 
and warnings given in the
manual to prevent injury to
both operator and client.

4. To access the control box to disconnect the hand control you must first 

remove the control box mounting bracket from the underside of 
the cabinet (head end) by unscrewing the four knobs that hold the 
bracket in place. Brace the bottom of the control box with one hand 
while loosening the knobs. Once the knobs are removed, rest the 
control box carefully down on the floor. There is plenty of excess cord
stored inside the cabinet to allow the control box to sit on the floor
and to rotate the mounting plate to face you.

5. Follow the coil cord for the hand control back to the place 

where it connects to the control box. Press down on the cord 
connector tab and unplug the hand control.

6. Pull on the hand control’s coil cord enough to enable you to 

reach the plastic cord restraint that holds the cords in place (the 
black foot control cord enters the control box here as well). 
Remove the plastic cord restraint by just applying a little pressure 
to one side. Slide the hand control cord out of the slit in the restraint.
Discard the inoperable control.

17

TROUBLESHOOTING

• Hand Control Replacement Instructions

TROUBLESHOOTING

TROUBLESHOOTING

• Hand Control

(cont)

(back of 
control box)

Summary of Contents for GMCTMP

Page 1: ...I N S T R U C T I O N M A N U A L OAKWORKS INSTRUCTION MANUAL Manual Part MMMNCG0109 Edition 3 English May 2007 Printed in U S A MASSAGE TABLES 64CA...

Page 2: ...ibility for any errors that may appear in this document nor does it make expressed or implied warranty of any kind with regard to this material including but not limited to the implied warranties of m...

Page 3: ...rranties of merchantability and fitness for a particular purpose Warranty valid with proof of purchase 26 Model No GMCTMP Celesta Gemini TABLE OF CONTENTS i TABLE OF CONTENTS Symbol Identification pg...

Page 4: ...1 Power Cord Main North America 1 7791 02 Power Cord United Kingdom 1 7791 03 Power Cord Europe Italy 1 7791 04 Power Cord Swiss 1 5589 Power Cord Japan 1 7791 06 Power Cord Australia 1 Celesta Gemini...

Page 5: ...lesta Gemini E L E C T R I C A L S P E C S T A B L E S P E C S 37 8cm L x 61 6cm H x 143 5cm W 34 3cm L x 61 6cm H x 55 2cm W 34 3cm L x 61 6cm H x 43 2cm W 34 3cm H x 51 1cm L 34 3cm H x 39 1cm L 37...

Page 6: ...and foot controls out of the way for moving Risk of Electrical Shock Connect this table to a properly grounded outlet only See Grounding Instructions Use this furnishing only for its intended use as...

Page 7: ...oft cloth and be careful not to get it onto other surfaces IMPORTANT CAUTION Before cleaning with any liquid cleaner be sure to un plug the power cord from the power outlet Do not operate the table in...

Page 8: ...s equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all l...

Page 9: ...custom designed high end furniture You will rely on the strength but all you will see is the beauty We ve gone to great lengths to hide the wiring on the Celesta Gemini for a streamlined glamour that...

Page 10: ...ason To do so could cause damage to the base and will void the warran ty There are no serviceable items that need this action Never lift the table by grasp ing the table top as the table top is not de...

Page 11: ...of cord closest to the plug into the slit of the plastic cord restraint The cords for both the hand control and the foot control will fit in to this slit Place the plastic cord restraint into the hole...

Page 12: ...the table top as the table top is not designed to hold the weight of the base and you could damage the table IMPORTANT Leveling Feet When operating the Celesta Gemini controls be sure to observe all c...

Page 13: ...he new unit will be reassembled in the same way CAUTION Before doing any work on the unit disconnect the power cord from the power outlet Be sure to read all cautions warnings and instructions given i...

Page 14: ...nal comfort and support when needed The Celesta Gemini weighs approximately 300 lbs You will need 4 people working together if it is necessary to move the table Never lift the table by grasping the ta...

Page 15: ...eep the 1st cam lock within 3 of the table to ensure a stable connection To remove the QuickLock Face Rest just pull the frame from the outlet until it comes free Set it safely aside or store it insid...

Page 16: ...s nearly limitless positioning options with the QuickLock Face Rest The adjustable pad takes pressure off sensitive facial areas while providing superb support The QuickLock Face Rest can be used in b...

Page 17: ...ed for storage or as an area to hold accessories while with a client DO NOT use this area for holding anything Damage can occur to the table especially when the pre set position commands that are acce...

Page 18: ...e way or remove them altogether We recommend that you raise the arm rest out of the way to allow a client to get on or off the table They are designed to be strong and will take a reasonable amount of...

Reviews: