1. Introduction

Thank you for purchasing an OAKTON

®

Acorn Meter. These meters are economical,

microprocessor-based meters that deliver ±0.01 pH accuracy.

Some of the features of these meters are:

• Large LCD for clear and easy reading

• pH 5 and pH 6 series meters allow measurement in pH and Temperature (°C)

• pH 6 series meters also allow measurement in Millivolt (mV), for taking 

ORP (Redox) readings or checking pH electrode performance.

This instruction manual is organized for easy reference. For basic functions of this
meter, read sections 2 through 5. These sections include basic instructions that will
get you up and running quickly. The remaining sections of this manual (6 through
11) deal with electrode maintenance, error messages and troubleshooting. This part
of the manual also includes the Specifications, Accessories, Warranty and Return of
Items section. 

2. Display and Keypad Functions

The Acorn has a large custom LCD with the following indicators:

pH

HO

LO

 C

mV

indicates 

operation mode

pH

annunciator

Degree C

annunciator

mV annunciator

(pH 6 only)

Reading

indicates

HOLD

function is

activated

indicates

low 

battery

condition

The OAKTON Acorn meter has four keys on its splashproof keypad. These keys are
ON/OFF, HOLD/ENTER, CAL and MODE.

ON/OFF:

Powers meter on and shuts 

unit off. Meter directly enters 
measurement mode when you 
turn it on.

HOLD/ENTER: 

Freezes the measured 

reading; confirms calibration value.

CAL: 

Allows calibration of the meter 

for pH, mV and Temperature

MODE/INC: 

Selects the parameter of 

measurement: pH, mV (pH 6 series 
only) and temperature.

ON

OFF

CAL

HOLD

ENTER

MODE

INC

Summary of Contents for pH 5+

Page 1: ...DISTRIBUTED BY 00702 41 OPERATING INSTRUCTIONS OAKTON WD 35613 00 01 10 11 pH 5 and pH 6 Acorn Series Meters Printed in the U S A 8 98 pH 6 Acorn series pH mV C Meter ON OFF CAL HOLD ENTER MODE INC...

Page 2: ...ng the Meter on 7 4 Calibration 8 10 4 1 pH Calibration 8 9 4 2 Temperature Calibration 9 4 3 Millivolt mV Calibration 10 5 Measurement 11 5 1 Taking Measurements 11 5 2 HOLD feature 11 6 Electrode Ca...

Page 3: ...ectrode maintenance error messages and troubleshooting This part of the manual also includes the Specifications Accessories Warranty and Return of Items section 2 Display and Keypad Functions The Acor...

Page 4: ...e electrode s connector push together and twist the electrode connector 1 2 turn until it clicks into place To remove simply rotate the connector counter clockwise until it unlocks and slide the conne...

Page 5: ...to indicate CAlibration See figure The display will then show the current noncalibrated reading blinking while in calibration mode See figure 5 Allow the reading to stabilize The meter auto matically...

Page 6: ...le value and then loops back to the minimum allowable value 4 Press ENTER key to confirm calibration The LCD displays CO and the meter then reverts to measurement mode 5 Measurement Taking Measurement...

Page 7: ...heat a diluted KCl solution for 60 80 C Place the sens ing part of the electrode into the heated solution for about 10 minutes Allow the electrode to cool in some unheated KCl solution Protein deposi...

Page 8: ...e and temperature probe WD 35613 11 Additional pH 6 Series Acorn Meter pH mV C with temperature probe electrode not included Accessories WD 35606 80 Protective Rubber Boot encases meter in sturdy rubb...

Page 9: ...to be free from significant deviations in material and workmanship for a period of six months from date of purchase If repair or adjustment is necessary and has not been the result of abuse or misuse...

Page 10: ...19 18...

Reviews: