![NXP Semiconductors S32K1 Series Hardware Design Manuallines Download Page 16](http://html.mh-extra.com/html/nxp-semiconductors/s32k1-series/s32k1-series_hardware-design-manuallines_1721893016.webp)
7.1.1 LIN components data
Table 5. LIN components
Reference
Part
Mounting
Remark
DMLIN
Diode
Mandatory only for master
ECU
Reverse Polarity protection
from LIN to VSUP.
RML1 and RML2
Resistor: 2 k
Ω
Power Loss: 250 mW
Tolerance: 1%
Package Size: 1206
Requirement:
Min Power rating of the
complete master termination
has to be ≥ 500 mW
Mandatory only for Master
ECU
For Master ECU
If more than 2 resistors are
used in parallel, the values
have to be chosen in a way
that the overall resistance RM
of 1 k
Ω
and the minimum
power loss of the complete
master termination has to be
fulfilled.
For Slave ECU
RMLIN1 and RMLIN2 are not
needed on the PCB layout
C1
Capacitor:
Slave ECU: typically 220 pF
Master ECU: from 560 pF up
to approximately ten times that
value in the slave node
[CSLAVE], so that the total line
capacitance is less dependent
on the number of slave nodes.
Tolerance: 10%
Package Size: 0805
Voltage: ≥50 V
Mandatory
The value of the master node
has to be chosen in a way that
the LIN specification is fulfilled.
C2
Capacitor:
Package Size: 0805
Optional
Mounting of the optional part
only allowed if there is an
explicit written permission of
the respective OEM available.
Place close to the connector.
ESD1
ESD Protection
Package Size: 0603-0805
Optional
Layout pad for an additional
ESD protection part.
Mounting of the optional part
only allowed if there is an
explicit written permission of
the respective OEM available.
Place close to the connector.
NXP Semiconductors
Communication modules
Hardware Design Guidelines for S32K1xx Microcontrollers , Rev. 3, December 2018
Application Note
16 / 33