22
•
•
Hazardous Radiation Exposure
Caution – Use of controls or adjustment or performance of procedures other than
those specified herein may result in hazardous radiation exposure.For products with
optical ports.
CLASS 1 LASER PRODUCT and reference to the most recent laser standards:
IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+ A2:20
Installation Procedure Overview
The installation procedure of ConnectX-6 Dx adapter cards for OCP Spec 3.0 involves the following
steps:
St
ep
Procedure
Direct Link
1
Check the system's hardware and software
requirements.
Refer to
2
Pay attention to the airflow consideration within the
host system
Refer to
3
Follow the safety precautions
Refer to
4
Follow the pre-installation checklist
Refer to
5
(Optional) Replace the assembled OCP 3.0 bracket
with the desired form factor bracket
6
Install ConnectX-6 Dx adapter card for OCP spec 3.0
in the system
Refer to
7
Connect cables or modules to the card
Refer to
8
Identify the ConnectX-6 Dx adapter card in the
system
Refer to
Identify the Card in Your System
System Requirements
Unless otherwise specified, NVIDIA products are designed to work in an environmentally
controlled data center with low gaseous and dust (particulate) contamination levels.
The operating environment should meet severity level G1 as per ISA 71.04 for gaseous
contamination and ISO 14644-1 class 8 for cleanliness level.