Important Installation Notes & Mounting Installation 

Receptacle Location: 

A conventional, wall-mounted, vertically-oriented, GFCI-Protected 15 Amp or 20 

Amp duplex receptacle under the skirt of the tub must be prepared, located in a 
sheltered area away from any possible contact with water (e.g. away from the 
tub deck, plumbing, and water pump). 

The Receptacle must be located well within the range of the tub’s power cord 

and must not be accessible to the user after the skirt is installed. 

Due to the need to mount the controller, do not use “Decora

-

style” 

receptacles, as these do not have a center screw. 

Load: 

This Controller is only compatible with 120 

Volt Brush-Type Pumps and Brush-Type 
Blowers, with a Maximum Rating of 12 Amps. 
Plug the Load into the Receptable at the 
bottom of the Control Box. Do not exceed the 
Electrical Ratings listed on the product label. 

Features:  

The Air Switch, Keypad, and/or Tub Lights are 

to be connected to the respective port of the 
Control Box. 

CAUTION 

Turn the power off at the breaker 

panel, and confirm that it is de-energized before 

installing. 

 

CAUTION 

Use a non-conductive plastic 

receptacle cover only. Do not use a metal cover. 

Metal covers could present a shock hazard if it was 

to fall across the Controller’s Power Blades if the 

power was accidentally left on during installation, 

removal, or servicing.

 

TO BATH PUMP OR 

BLOWER

 

Summary of Contents for TOUCHSTONE CSLC-317-02-01-01

Page 1: ...317 02 01 01 Single Load Controller Multi Speed Triac Load Installation Operating Manual with Troubleshooting and Configuration Guide NuWhirl Systems Corp www nuwhirl com 951 817 5600 MANCSLC31702 REV...

Page 2: ...by a Ground Fault Circuit Interrupter GFCI Contact a qualified electrician if you cannot verify that the power supply is protected by a GFCI The GFCI should be tested on a routine basis Consult the G...

Page 3: ...ration P 4 Important Installation Notes Mounting P 6 CSLC 317 02 01 01 Multi Speed Air Blower Triac Model Installation Feature Operations P 8 Operations P 10 System Troubleshooting P 14 All Installati...

Page 4: ...hese are the configurations currently available as of September 22 2021 CSLC 317 02 01 01 Triac Model CAUTION Ensure that the Controller Model is suitable for the Tub s Load that is to be controlled F...

Page 5: ...from the AC power and wait about 10 seconds 3 Plug the control box back in The green Power LED will blink the current configuration that it is in 4 Within 20 seconds press and hold the Configuration B...

Page 6: ...t have a center screw Load This Controller is only compatible with 120 Volt Brush Type Pumps and Brush Type Blowers with a Maximum Rating of 12 Amps Plug the Load into the Receptable at the bottom of...

Page 7: ...overtighten 4 Turn the power back on and confirm correct operation Note If the remaining receptacle above the Controller is being used the total load must not exceed the circuit s rating Additional In...

Page 8: ...12 CICL 297 Tub Lights x2 Max Configs 1 thru 6 Air Switch Option Configs 1 7 thru 12 To 120V GFCI Protected Receptacle 15A or 20A Duplex Female Socket TO PUMP OR BLOWER Max 12A Load CCBL 372 CCBL 366...

Page 9: ...to fully understand and safely utilize the tub System Features Air Buttons Function Timers Variable Speed Pump or Variable Speed Blower Multi Color LED Tub Lights Activation Air Switch Buttons which m...

Page 10: ...its 30 minute timer and activate the Tub Light in a Rainbow mode Subsequent presses will change the color to Blue White Blue Aqua Green Yellow Red Magenta and off The Tub Light will turn off automati...

Page 11: ...the Blower on at high speed and activate its 30 minute timer Subsequent presses will change the speed to medium low oscillate mode and off The system will stop automatically when the timer expires The...

Page 12: ...the speed to medium low oscillate mode and off The system will stop automatically when the timer expires Configuration 8 Variable Speed Pump w Oscillation Option No Light The Whirlpool Water system is...

Page 13: ...the Button a third time turn the Blower off Configuration 12 Variable Speed Blower w Oscillation Option No Light 24 Hour Purge Cycle The Air System is activated by pressing the Air Air Button The Air...

Page 14: ...f these cables were cross connected or forced in at any point irreparable damage may result and any warranty will be void Should this happen replace all the affected components ensuring that they are...

Page 15: ...not function verify that the Load is operational by plugging it directly into a known good wall receptacle If not replace the Control Box or Load accordingly Non Functional Keypad If the Keypad is not...

Page 16: ...tems Corp www nuwhirl com 951 817 5600 MANCSLC31702 REV A 9 27 2021 Retain this manual for future reference For your records and future reference please fill in data below Manufacturer Model Serial Da...

Reviews: