Important Installation Notes & Mounting Installation
Receptacle Location:
A conventional, wall-mounted, vertically-oriented, GFCI-Protected 15 Amp or 20
Amp duplex receptacle under the skirt of the tub must be prepared, located in a
sheltered area away from any possible contact with water (e.g. away from the
tub deck, plumbing, and water pump).
The Receptacle must be located well within the range of the tub’s power cord
and must not be accessible to the user after the skirt is installed.
Due to the need to mount the controller, do not use “Decora
-
style”
receptacles, as these do not have a center screw.
Load:
This Controller is only compatible with 120
Volt Brush-Type Pumps and Brush-Type
Blowers, with a Maximum Rating of 12 Amps.
Plug the Load into the Receptable at the
bottom of the Control Box. Do not exceed the
Electrical Ratings listed on the product label.
Features:
The Air Switch, Keypad, and/or Tub Lights are
to be connected to the respective port of the
Control Box.
CAUTION
Turn the power off at the breaker
panel, and confirm that it is de-energized before
installing.
CAUTION
Use a non-conductive plastic
receptacle cover only. Do not use a metal cover.
Metal covers could present a shock hazard if it was
to fall across the Controller’s Power Blades if the
power was accidentally left on during installation,
removal, or servicing.
TO BATH PUMP OR
BLOWER