OPI-POWER LIFT HF 3S 8000-V1.0-EN
51
Regular safety inspection and maintenance
i
Copy, complete and leave in the inspection book
Serial number: _________________________________
Test step
OK
Defect
Reinspect
Remarks
missing
Model plate .......................................................
□
.................
□
................
□
_______________________________
Brief operating instructions on the column ...
□
.................
□
................
□
_______________________________
Load capacity details on the lift ....................
□
.................
□
................
□
_______________________________
Detailed operating manual .............................
□
.................
□
................
□
_______________________________
Condition, function operating lever and button
□
.................
□
................
□
_______________________________
Label “LIFT, LOWER” ..........................................
□
.................
□
................
□
_______________________________
Condition, lockable main switch ...................
□
.................
□
................
□
_______________________________
Condition, rubber plate ..................................
□
.................
□
................
□
_______________________________
Securing the lifting arm bolts ..........................
□
.................
□
................
□
_______________________________
Secure the receiving plate (not unscrewable)
□
.................
□
................
□
_______________________________
Condition, function carrier plate ....................
□
.................
□
................
□
_______________________________
Condition, function foot bumper (optional) ..
□
.................
□
................
□
_______________________________
Condition, function safety catch ....................
□
.................
□
................
□
_______________________________
Condition sliding part lift rails ..........................
□
.................
□
................
□
_______________________________
Paint condition .................................................
□
.................
□
................
□
_______________________________
Load bearing construction (deformations, cracks)
□
.................
□
................
□
_______________________________
Fastening screw torque ...................................
□
.................
□
................
□
_______________________________
Nuts Cylinder mounting set correctly .............
□
.................
□
................
□
_______________________________
Nuts Cylinder Mount: Check Sealing Wax
.....
□
.................
□
................
□
_______________________________
Fastening anchor torque ................................
□
.................
□
................
□
_______________________________
Condition, function lifting arm block .............
□
.................
□
................
□
_______________________________
Condition, function lifting arm movement ....
□
.................
□
................
□
_______________________________
Condition, safety plate on Mini-Max
.............
□
.................
□
................
□
_______________________________
Condition, function of Mini-Max lifting arm
...
□
.................
□
................
□
_______________________________
Condition of cross-beam ................................
□
.................
□
................
□
_______________________________
Cylinder condition ...........................................
□
.................
□
................
□
_______________________________
Condition wiper cylinder .................................
□
.................
□
................
□
_______________________________
Condition of covers .........................................
□
.................
□
................
□
_______________________________
Condition, function riser extension
.................
□
.................
□
................
□
_______________________________
Condition of concrete floor (cracks)
.............
□
.................
□
................
□
_______________________________
Condition electrical lines .................................
□
.................
□
................
□
_______________________________
Condition, hydraulic lines + screw fittings
..........
□
.................
□
................
□
_______________________________
Condition, hydraulic unit .................................
□
.................
□
................
□
_______________________________
Functional test lift with vehicle ........................
□
.................
□
................
□
_______________________________
Functional test “overflows”
.............................
□
.................
□
................
□
_______________________________
Stability of lift .....................................................
□
.................
□
................
□
_______________________________
General condition of lift ..................................
□
.................
□
................
□
_______________________________
*) Place a checkmark in the relevant, if a retest is required then check it again!
Safety inspection done on:
_________________________________________________________________
Performed by company:
_________________________________________________________________
Name, address of specialist:
_________________________________________________________________
Result of inspection:
□
Continued operation questionable, reinspection required
□
Continued operation possible, remove defects by ___________________
□
No deficiencies, continue to operate
______________________________ ______________________________
Signature of specialist
Operating company signature
If requested to take care of deficiencies
Deficiency removed on:
______________________________
______________________________
Operating company signature
(Use a new form for reinspection!)
Summary of Contents for HF 3S 8000
Page 2: ...2 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Page 4: ......
Page 18: ...18 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Page 19: ...OPI POWER LIFT HF 3S 8000 V1 0 EN 19 ...
Page 20: ...20 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Page 21: ...OPI POWER LIFT HF 3S 8000 V1 0 EN 21 ...
Page 55: ...Made in Germany POWER LIFT HF 3S 8000 Made in Germany Spare parts list ...