OPI-POWER LIFT HF 3S 8000-V1.0-EN
39
• Move the lift rails to about half height.
• Remove the lifting arm (remove the safety ring of
the lifting arm pin, pull out the lifting arm pin and
remove the lifting arm).
• Disconnect electrical supply lines to the lift from
mains power.
• Remove hydraulic lines above on the opposite
side and seal them off with blind stoppers.
• Only loosen cross beams on one side and fold
them under along with the hydraulic lines.
•
Securely fix the beam to the columns.
• Suction off hydraulic oil.
• Loosen the anchor fastenings.
• Carefully transport the lift column using appropri-
ate auxiliary means (e.g. crane, forklift, etc) to the
new assembly location.
• Assemble the lift according to the procedure
during assembly and anchoring before first com
-
missioning.
!
Use new anchors. The old anchors are no longer
fit for purpose.