Summary of Contents for Aeware Advanced in.k600

Page 1: ...TechBook Swimspasolution Makeyourswimspa installationmoreflexible...

Page 2: ...r condition 39 LLEr 40 speci cations 41 Table of contents introduction 3 warnings 4 Swim Spa overview in k600 dimensions 5 in k100 dimensions 6 keypad installation connections 7 plumbing 8 in xe conne...

Page 3: ...2 Swim Spa Solution...

Page 4: ...ce and an in k100 auxiliary keypad An interface cable 8 is provided with the kit to link the in xe controls together Information is exchanged between the two in xe controls allowing the exibility to c...

Page 5: ...LY FLAMMABLE MATERIALS LOW VOLTAGE OR IMPROPER WIRING MAY CAUSE DAMAGE TO THIS CONTROL SYSTEM READ AND FOLLOW ALL WIRING INSTRUCTIONS WHEN CONNECTING TO POWER SUPPLY warnings THIS PACK CONTAINS NO SER...

Page 6: ...neral speci cations Environmentals Storage temperature 85 C 185 F to 30 C 22 F Operating temperature 65 C 149 F to 20 C 4 F Humidity up to 95 condensing Mechanical Specs Weight 0 4763 Kg 1 05 lbs Dime...

Page 7: ...temperature 70 C 158 F to 30 C 22 F Operating temperature 60 C 140 F to 20 C 4 F Humidity 100 condensing Mechanical Specs Weight 0 41 kg 0 9 lbs Dimensions W x H x D Front Panel 130 2mmx42 9mmx52 4mm...

Page 8: ...evenly on the entire surface Installation in k600 TM Optional wing nuts and spacers 7 250 3 750 keypad installation connections Installation in k100 TM To install the in k100 TM determine the mounting...

Page 9: ...8 Swim Spa Solution plumbing Swim spa installation scheme XP2 water jet MASTER in xe spa lter ow spa SLAVE in xe ow ow Requirers a minimum of 18 GPM About 2...

Page 10: ...ng Push the color coded wires into the terminals as indicated on the sticker and use the at screwdriver to tighten the screws on the terminals After making sure wire connec tions are secure push them...

Page 11: ...N WHITE BLACK RED G L2 N L1 GREEN WHITE BLACK RED WARNING This wiring diagram is for reference use only In the event of discrepancies between this wiring diagram and any federal state or local Electri...

Page 12: ...TE BLACK RED G L2 N L1 GREEN WHITE BLACK RED electrical wiring WARNING This wiring diagram is for reference use only In the event of discrepancies between this wiring diagram and any federal state or...

Page 13: ...L1 GREEN BLUE BROWN G N L2 L1 GREEN BLUE BROWN WARNING This wiring diagram is for reference use only In the event of discrepancies between this wiring diagram and any federal state or local Electrical...

Page 14: ...1 GREEN BLUE BROWN G N L2 L1 GREEN BLUE BROWN WARNING This wiring diagram is for reference use only In the event of discrepancies between this wiring diagram and any federal state or local Electrical...

Page 15: ...GREEN BLUE BLACK G N L2 L1 GREEN BLUE BLACK BROWN WARNING This wiring diagram is for reference use only In the event of discrepancies between this wiring diagram and any federal state or local Electri...

Page 16: ...d to insure safe and ef cient current management and no GFCI trippings Press and hold Prog button until you access the breaker setting menu The values displayed by the system correspond to 0 8 of the...

Page 17: ...of this manual Programming the in xe using the in stik This feature is very useful on production lines to con gure packs and in the eld for service purposes like software updates Follow these simple...

Page 18: ...re enter the low level programming menu using the keypad 3 Press the Prog key to con rm the selected con guration consult the low level con guration selection chart section of this manual NOTE If the...

Page 19: ...Filter cycle with P1 Clean P1L P1 Page 19 4 2sp 2sp 1sp 1sp X On during Filter cycle with P1 Clean P1L P1 Page 20 5 2sp 1sp 1sp 1sp X On during Filter cycle with P1 Clean P1L P1 Page 21 6 2sp 1sp 1sp...

Page 20: ...on Con guration 1 3 4 Pump System connections Master Slave XP3 XP3 XP2 XP2 Ozonator in k100TM Cable in tr LV LV 8KCO Pump 2 Pump 1 Pump 4 Pump 3 in k600TM CoolRaysTM CoolRaysTM 9920 401316 in powerTM...

Page 21: ...er Slave XP3 XP3 XP2 XP2 Ozonator in k100TM Cable in tr LV LV 8KCO Pump 2 Pump 1 Pump 4 Pump 3 in k600TM CoolRays CoolRays 9920 401316 in powerTM in p3TM in chantTM Blower Con guration 2 4 4 Pump and...

Page 22: ...5 5 Pump System connections Master Slave XP3 XP3 XP3 XP2 XP2 Ozonator in k100TM Cable in split 9920 401248 Cable in tr LV LV 8KCO 9920 401316 Pump 2 Pump 1 Pump 4 Pump 5 Pump 3 in k600TM CoolRays Cool...

Page 23: ...on 6 5 Pump and Blower system Master Slave XP3 XP3 XP3 XP2 XP2 Ozonator in k100TM Cable in split 9920 401248 Cable in tr LV LV 8KCO 9920 401316 Pump 2 Pump 1 Pump 4 Pump 5 Pump 3 in k600TM Blower Cool...

Page 24: ...a Solution Con guration 7 3 Pump System connections Master Slave XP3 XP2 XP2 Ozonator in k100TM Cable in tr LV LV 8KCO Pump 2 Pump 1 Pump 3 in k600TM CoolRays CoolRays 9920 401316 in powerTM in p3TM i...

Page 25: ...rameter Display Options Description Output 1A 1H 1L 2H 2L 3H 3L 4H 4L P5 BL CP O3 L2 H Accessory connected to the relay of Output 1A Output 1B 1H 1L 2H 2L 3H 3L 4H 4L P5 BL CP O3 L2 H Accessory connec...

Page 26: ...r Heater Pump Circulation pump 0 Pump 1 1 Pump associated with the Heater Filter Con g Purge only 0 With Circ Pump 1 With Pump 1 Low speed 2 Filter cycle con guration Temp Units F 0 C 1 Temperature un...

Page 27: ...accessory connected to the relay of Output 4A Output 5 current 1 to 17 amperes Current draw of the accessory connected to the relay of Output 5A Direct current 0 to 5 amperes Current draw of the Dire...

Page 28: ...dition or a problem which needs to be corrected to ensure proper functioning of the system The error code and the water temperature are alternately displayed If there is more than one active error the...

Page 29: ...k Temperature inside the spa skirt is too high causing the internal temperature in the in xe to exceed normal limits Prr means the error comes from the MASTER pack Pr2 means the error comes from the S...

Page 30: ...wim spa con guration and a SLAVE pack has been detected in xe error codes LLXX Unable to select the desired low level when you con rm it goes back into the low level menu SLA The pack on which the mai...

Page 31: ...rdware error has been detected MASTER pack Restart the Spa Pack and start stop all outputs Replace Spa Pack if problem persist Flow chart An internal hardware error has been detected SLAVE pack Hr or...

Page 32: ...Pack no Pump is overheating water during lter cycle Lower lter cycle duration Reset system Verify if anything is obstructing water ow closed traps or dirty lters Reset system Verify if Hi Limit probe...

Page 33: ...There must be adequate water in spa for normal use a minimum of 18 gpm must circulate through the heater yes Is pump working when you try to start it from keypad no Refer to Pump not Working section...

Page 34: ...ist Measure water temperature with a DIGITAL thermometer Are you getting correct tempe rature reading on the keypad display yes no Add cold water and lower lter cycles Replace heater if problem persis...

Page 35: ...f regulation probe is properly connected Replace heater if problem persist Regulation probe issue MASTER pack Replace Spa Pack if problem persist Flow chart Prr or Pr2 error condition ow chart or Regu...

Page 36: ...erature inside the spa equipment compartment is too high MASTER pack Remove spa skirt and let system cool down until the error clears Replace Spa Pack if problem persist Flow chart Temperature inside...

Page 37: ...s to be downloaded into the in xe spa system without it the system will not be operable Contact our toll free line for technical support 1 800 784 3256 No low level con guration software in system Not...

Page 38: ...es no Run a visual ins pection of both CO connectors to look for bent pins you should see 8 straight pins Are there bent pins Flow chart Verify the connection between the 2 packs Ensure that the in li...

Page 39: ...in keypad is connected on the pack with a SLAVE con guration SLA error condition ow chart The main keypad is connected on the pack with a SLAVE con guration Change the connection of the main keypad to...

Page 40: ...e to select the desired low level when you con rm it goes back into the low level menu Unable to select the desired low level when you con rm it goes back in the menu Replace SLAVE pack Flow chart LLX...

Page 41: ...error condition ow chart The selected con guration is not a swim spa con guration and a SLAVE pack has been detected Flow chart Remove the SLAVE pack Is it really the con guration you want yes no Sel...

Page 42: ...Light 12V 1 A Output 5 Heater 240V 4 0 kW The total maximum amperage for blower circ pump and Direct cannot exceed 12 Amps speci cations Slave in xe Output Voltage Current Output 1A Pump3 1 speed 120...

Page 43: ...c pump and Direct cannot exceed 12 Amps Slave in xe Output Voltage Current Output 1A Pump 3 1 speed 230V 7 5 FLA 60 LRA Output 1B Pump 4 1 speed 230V 15 FLA 60 LRA Output 2 Pump 5 1 speed 230V 7 5 FLA...

Page 44: ...ed in link connection HC LC or low voltage is plugged with the appropriate blank plug The in xe ce is lab tested to IPx5 enclosure protection levels Environmental Operating temperature 0 C 32 F to 50...

Page 45: ...450desCanetons QuebecCity QC G2E5W6Canada 1 800 78 GECKO 9225StellarCourt Corona CA92883USA 951 667 2000 www geckoalliance com 9919 101142 Rev 04 11 2010GroupeGeckoAllianceInc TMtrade marksof marquesd...