30
OPI-POWER LIFT HF 3S 8000-V1.0-EN
Time frame
Position
Type of
maintenance
Person in
charge
Maintenance plan
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
All weld seams must have a visual inspection. Stop
the system and contact the manufacturer if there are
cracks or breaks in weld seams of the lift.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Check electrical components for function and con-
dition.
• Plug.
• Operating lever with button switch.
• During assembly and maintenance always check
the condition of electrical lines. All cables and lines
must be secured so they cannot be crushed, kinked
or contact any moving assembly.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Optional energy set:
• Electrical socket
• Pneumatic connection
Check for condition and function.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Check the paint:
• Check the powder coating and improve if required.
Damage by external influences is to be treated im
-
mediately after detection. If these points are not
treated, infiltration of deposits of all kinds can cause
wide-ranging and permanent damage.
These points are to be lightly sanded (120 grit),
cleaned and degreased. Afterwards, rework with a
suitable touch up paint (note the RAL No.).
• Check galvanised surfaces, touch up as needed.
White rust is fostered by permanent humidity, poor
ventilation. The affected areas can be treated by
using a sanding cloth (A 280 grit). If required, the
parts are to be treated with a suitable, resistant ma-
terial (paint etc.). Check the RAL colour selection.
• Rust is brought out by mechanical damage, wear,
aggressive deposits (de-icing salt, leaking operating
fluids) cleaning that is not done or incomplete.
The affected areas can be treated by using a sand-
ing cloth (A 280 grit). If required, post-treat the areas
with a resistant material (paint etc.).
Summary of Contents for HF 3S 8000
Page 2: ...2 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Page 4: ......
Page 18: ...18 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Page 19: ...OPI POWER LIFT HF 3S 8000 V1 0 EN 19 ...
Page 20: ...20 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Page 21: ...OPI POWER LIFT HF 3S 8000 V1 0 EN 21 ...
Page 55: ...Made in Germany POWER LIFT HF 3S 8000 Made in Germany Spare parts list ...