22
GB
2. AIR FILTER (PER 50H OR PER ONE MONTH) (PIC. 11)
2.1 Remove air filter.
2.2 Wash clearly in solvent.
2.3 Get Motor oil.
2.4 Squeeze Motor oil out.
WARNING: Never run engine without the filter.
3. FUEL COCK AND FUEL TANK FILTER (PER 150H OR PER
THREE MONTHS) (PIC. 12 - 13)
3.1 Clear fuel cock.
3.1.1 Stop engine.
3.1.2 Turn fuel cock lever to «OFF».
3.1.3 Clear with solvent.
3.2 Clear fuel tank filter.
3.2.1 Clear in solvent.
3.2.2 Wipe off.
3.2.3 Insert into fuel tank.
WARNING: Remember that spent oils, battery fluids and all
the filters of the machine MUST BE DISPOSED OF according
to laws on protection of the environment and current
legislation, as these are polluting products.
9 - PERIODIC MAINTENANCE CHART
Item
Operation
Every
50 hours
Every
150 hours
Spark plug
Clean dirt with iron brush between spark plug gap.
Set spark plug gap.
Change if necessary.
X
Air filter
Clean. Change if necessary.
X
Fuel filters
Clean. Change if necessary.
X
10 - STORAGE
If the generator is not to be used or is to be stored for more than
one month, follow these instructions:
1. Drain all the fuel from the fuel tank and the carburetor.
2. Shake the tank till all the excess being drain off.
3. Remove spark plug and fill cylinder with a spoon of fresh
oil, and start engine for a few times to distribute oil, then
reassemble spark plug.
4. Store the generator set in a dry, well ventilated place, under a
cover.
THE INSTALLATION AND MAJOR REPAIR WORK SHALL
BE CARRIED OUT ONLY BY SPECIFICALLY TRAINED
PERSONNEL.