G3 Series EtherNet/IP
TM
Technical Manual
Page 8-77
TDG3EPTM1-9EN
05/18
Subject to change without notice
www.asco.com/g3
8.7
Sub-bus Valve Module
Used to control a distributed valve manifold through the Sub-Bus. See page 53 for
more information.
Module
Part No.
I/O Type
Short Circuit Protection
Short Circuit
Protection Status Bits
Output Points
240-241
NPN (Sinking)
YES – Visual
YES (32) – Optional
32
Output Mapping
BYTE
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
X
(Required)
Valve
Coil No.
7
Valve
Coil No.
6
Valve
Coil No.
5
Valve
Coil No.
4
Valve
Coil No.
3
Valve
Coil No.
2
Valve
Coil No.
1
Valve
Coil No.
0
X+1
(Selectable)
Valve
Coil No.
15
Valve
Coil No.
14
Valve
Coil No.
13
Valve
Coil No.
12
Valve
Coil No.
11
Valve
Coil No.
10
Valve
Coil No.
9
Valve
Coil No.
8
X+2
(Selectable)
Valve
Coil No.
23
Valve
Coil No.
22
Valve
Coil No.
21
Valve
Coil No.
20
Valve
Coil No.
19
Valve
Coil No.
18
Valve
Coil No.
17
Valve
Coil No.
16
X+3
(Selectable)
Valve
Coil No.
31
Valve
Coil No.
30
Valve
Coil No.
29
Valve
Coil No.
28
Valve
Coil No.
27
Valve
Coil No.
26
Valve
Coil No.
25
Valve
Coil No.
24
Diagnostics
BYTE
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
X
(Selectable)
Coil 7
Status
Coil 6
Status
Coil 5
Status
Coil 4
Status
Coil 3
Status
Coil 2
Status
Coil 1
Status
Coil 0
Status
X+1
(Selectable)
Coil 15
Status
Coil 14
Status
Coil 13
Status
Coil 12
Status
Coil 11
Status
Coil 10
Status
Coil 9
Status
Coil 8
Status
X+2
(Selectable)
Coil 23
Status
Coil 22
Status
Coil 21
Status
Coil 20
Status
Coil 19
Status
Coil 18
Status
Coil 17
Status
Coil 16
Status
X+3
(Selectable)
Coil 31
Status
Coil 30
Status
Coil 29
Status
Coil 28
Status
Coil 27
Status
Coil 26
Status
Coil 25
Status
Coil 24
Status