32
www.numatic.co.uk
Trouble Shooting
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or
Numatic Technical he44 (0)1460 269268
(UK) Specifications
Model - CRG 8055 / 8072
(Empty) Net Weight
120 A/Hr
Brush Weight
Brush Width
Brush
Pressure
Pad
Width
Pad
Pressure
Brush Motor
Vac
Motor
CRG 8055 - 200 kg
CRG 8072 - 220 kg
CRG 8055 - 17 kg
CRG 8072 - 32 kg
550 mm
370mm x 2
8.4 G/cm
2
19.9 G/cm
2
508 mm
360mm x 2
6.8 G/cm
2
16.6 G/cm
2
24 V
600 W
24 V
400 W
Transaxle
Run Time
2 x 120 A/Hr
Run Time
2 x 100 A/Hr
Total Battery
Weight 120 A/Hrs
Total Battery
Weight 100 A/Hrs
Charge Times
2 x 120 A/Hrs
Charge Times
2 x 100 A/Hrs
24 V
400 W
3 Hrs
2 Hrs
74 kg
(163 lbs)
62 kg
(136 lbs)
10A = 12 Hrs
20A = 7 Hrs
10A = 8 Hrs
20A = 5-6 Hrs
Brush Speed
Airflow
Transit Speed
Capacity
Water Flow Rate
Cleaning Area
Sound Pressure
150 rpm
24.2 L/sec
0-6 Km/hr
80L / 80L
0 - 3
L/min
CRG 8055 - 1700m
2
@ 3.5 K/Hr
CRG 8072 - 2200m
2
@ 3.5 K/Hr
≤ 70dB (A)
Hand Arm Vibration
Whole Body Vibration
Height
Length
Width
Max Gradient
Travelling (Quarry Tiles)
1.84 m/s
2
(Uncertainty 0.92 m/s
2
)
ISO 5439-1
Travelling (Quarry Tiles)
1.11 m/s
2
(Uncertainty 0.56 m/s
2
)
ISO 2431-1
1160 mm
1460 mm
CRG 8055 - 805 mm
CRG 8072 - 948mm
11%
PROBLEM
CAUSE
SOLUTION
Machine will not operate
Missing or blown fuses
Low battery charge
Machine is connected and charging
Key is off or missing
Handle safety fuse blown
Fit or replace fuse (page 3 & 5)
Charge batteries (page 15 / 16)
Take off charge (page 15)
Insert key & turn to operating position
Replace fuse - No 19 (page 2 / 3) (or contact service engineer)
Vacuum will not operate
Missing or blown fuse
Vacuum switch not engaged
Waste water tank full
Fit or replace fuse (page 3 & 5)
Press switch (page 9)
Empty waste water tank (page 12)
Poor water pick-up
Waste water tank full
Clogged / blocked vacuum hose
Loose hose connections
Debris basket filter clogged / blocked
Separator filter clogged / blocked
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Damaged floor tool blades
Low battery charge
Floor tool incorrectly adjusted
Empty waste water tank (page 12)
Remove and clean (page 12)
Push tight connections (page 6)
Remove and clean (page 13)
Remove and clean (page 12)
Clean and refit (page 12)
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)
Re-charge batteries (page 15 / 16)
Adjust floor tool (page 11)
No brush / scrub function
No brushes fitted
Brush deck raised
Missing or blown fuses
Check and fit (page 7)
Lower brush deck (page 7 & 11)
Fit or replace fuse (page 3 & 5)
Little or no water flow
Clean water tank empty
Clean water tank filter blocked / clogged
Water flow not on
Brush deck raised
Blown pump fuse
Fill clean water tank (page 8)
Remove and clean (13)
Switch on water flow (Page 9)
Lower brush deck (page 7 & 11)
Replace fuse - No 20 (page 2 / 3)
Machine just ‘stops’ during
operating
Brush motor fuse blown due to high load
Handle safety fuse blown
Replace fuse & reduce load (page 3 & 5)
Replace fuse - No 19 (page 2 / 3) (or contact service engineer)
Summary of Contents for CRG 8055/100T
Page 49: ...49 T 01460 68600 EU Declaration of Conformity...
Page 50: ...50 www numatic co uk Notes...
Page 51: ...51 T 01460 68600 Notes...