60 Sets Measurement Values
25
Specifications
BW2110
LCD Digital Display
Oscillometric Method
Measurable
Model No.
Display
Measuring Principle
Circumference of Wrist
13.5~21.5cm (5.3''~8.5'')
Electric Shock Protection
Measurement
Range
Accuracy
Pressure
Pulse
Pressure
Pulse
Pressure
0 to 299 mmHg (0~39.9 kPa)
40 to180 Pulses/min
3 Digits Display of mmHg or kPa
3 Digits Display
Memory/IHB/Heartbeat/Low Battery,etc.
3 mmHg (0.4kPa)
5% of reading
Pulse
Internal power supply appliance type B
LCD
Indication
Symbol
26
Specifications
10 ~ 40 C (50 ~ 104 F)
15 ~ 90%RH (Noncondensing)
-20 ~ 60 C (-4 ~ 140 F)
10 ~ 95%RH (Noncondensing)
Temperature
Humidity
Temperature
Humidity
Barometric Pressure
Automatic by Internal Pump
Automatic by Air Valve
In 2 Minutes
Approx. 87*84*36mm
Operating
Environment
Memory Function
Inflation
Power Source
Rapid Air Release
Automatic Power-Off
Dimensions
Approx. 110g (Batteries not included)
Gross Weight
80~105 kPa
2 AAA Alkaline Batteries
28
27
Warranty Information
Federal law restricts this device to sale by or on the order of a physician.
Unit subjected to misuse, abuse, and neglect of these manual contents,
non-instructional purposes;unauthorized repair or modifications will be excluded
from this warranty. This guarantee specifically excludes expendables and
consumables, for example batteries.All warranty claims must be directed to the
distributor responsible for the sale of the device. The content of this warranty is
subject to change without further notice.
For repair under this warranty.Our authorized service agent must be advised of
the fault within the period of the warranty.This warranty covers parts and labor
only under normal operations.A transportation fee or freight fee that may be
incurred will be the owner’s responsibility.Any defect resulting from natural
causes, e.g.,flood,hurricane etc., is not within this guarantee.
This guarantee does not cover damage incurred by use of the unit not in
accordance with the instructions, accidental damage, or being tampered with or
serviced by unauthorized service agents.
The unit, excluding the unit cuff, is guaranteed to be free of defects in
workmanship and materials for a period of two years from the date listed on the
purchase record, when used in accordance with the instructions provided with the
unit.The unit cuff is warranted to be free from defects in materials and
workmanship appearing within one year from the date listed on the purchase
record when the unit is used in accordance with the instructions provided with the
unit.
Statement
The intended use: The unit is intended to be used by adults at home or medical
centre to measure blood pressure and pulse rate.
The unit satisfies the requirements of IEC60601-1 Medical electrical equipment,
EN1060-1: Non-invasive sphygmomanometer, EN1060-3: Non-invasive
sphygmomanometer,IEC80601-2-30: Medical electrical equipment.
The unit has passed the EMC Test.
Blood pressure measurements determined with this device are equivalent to
those obtained by a trained observer using the cuff/stethoscope auscultatory
method, within the limits prescribed by the American National Standard,
Manual, electronic, or automated sphygmomanometers.
The risk of patient and user can be lowered to acceptable level.
Substitution of a cuff different from that supplied might result in measurement error.
Please contact us if you need the circuit diagrams, component part lists etc.
Specifications are subject to change without notice due to improvements in
performance.
Transport and
Storage
Environment