nubeca BW2110 Instruction Manual Download Page 2

2

Important Safety Notes

Read all information in the instruction manual and any other 

literature included in the box before using the unit.
Contact your physician for specific information about your blood pressure. 
Self-diagnosis and treatment using measured results may be dangerous.Follow 
the instructions of your healthcare provider.
Operate the unit only as intended. Don't use for any other purpose.
The unit is intended to use in measuring blood pressure and pulse rate for adult 
only, not recommended for neonatal baby at home or medical centre.
Do not use a cellular phone near the unit. It may result in operational failure.
Please avoid using in high radiant area in order to make your measuring data 
correctly.
Do not disassemble or attempt to repair the unit or components.
Do not use the equipment where flammable gas (such as anesthetic gas, 
oxygen or hydrogen) or flammable liquid (such as alcohol) are present.

To assure the correct use of the product basic safety measures 

should always be followed including the precautions listed below:

3

Symbols Use

Indicates a potentially hazardous situation

Type B applied part

Refer to instruction manual/booklet

MANUFACTURER

SERIAL NUMBER

The marking of electrical and electronics devices 

according to Directive 2002/96/EC.

The device,accessories and the packaging have to be disposed

of waste correctly at the end of the usage.

Please follow Local Ordinances or Regulations for disposal.

AUTHORISED REPRESENTATIVE IN THE 

EUROPEAN COMMUNITY

which, if not 

avoided, could result in death or serious injury.

         SYMBOLS USED IN THIS INSTRUCTION MANUAL

WARNING

CAUTION

Indicates a potentially hazardous situation which, if not  

avoided, may 

 result in minor or moderate injury to the user or 

patient or damage to the equipment or other property. 

1

Introduction

Thank you for purchasing Fully Automatic Wrist Style Digital Blood Pressure 
Monitor.
The unit uses the oscillometric method of blood pressure measurement. It 
means the unit detects the movement of your blood through your brachial 
artery, and converts your blood pressure into a digital reading. The unit is 
simple to use because a stethoscope is not needed while using an 
oscillometric monitor.
The unit stores automatically 60 sets of measurement values . You can read 
the stored data conveniently by pressing the memory button.
The unit comes with the following components:

• Main Unit
• Storage Case 
• Instruction Manual printed in English

  

Body & Cuff

4

Know Your Unit

f

Wrist Cuf

Battery Compartment

Start/Stop Button

Memory Button
Memory Button

Display

Summary of Contents for BW2110

Page 1: ...ttery lnstallation Replacement 8 9 Adjusting Settings 10 Proper Way of Measurement 11 Take a Measurement 12 13 Use the Memory Function To read the average value 14 To read the measurement value 15 To...

Page 2: ...RER SERIAL NUMBER The marking of electrical and electronics devices according to Directive 2002 96 EC The device accessories and the packaging have to be disposed of waste correctly at the end of the...

Page 3: ...ol smoking exercising and bathing for 30 minutes before taking a measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or r...

Page 4: ...Then press the MEM up button to change the current unit Press the START STOP button to save the current setting and turn off 11 Proper Way of Measurement 1 Wrap the cuff tightly around your wrist by...

Page 5: ...and pulse rate in the memory after completing a measurement every time It can automatically store 60 sets of measurement values The oldest record is deleted to save the latest measurement value when...

Page 6: ...on s systolic and diastolic pressures fall into different categories the higher category should apply WHO 80 85 90 100 110 Diastolic Blood Pressur mmHg 120 130 140 160 180 Systolic Blood Pressure mmHg...

Page 7: ...rs on the display screen No power Causes and Solutions Problem Eliminate Fault Replace both of the worn batteries with two new ones 23 Care and Maintenance Care Avoid subjecting the monitor to strong...

Page 8: ...operations A transportation fee or freight fee that may be incurred will be the owner s responsibility Any defect resulting from natural causes e g flood hurricane etc is not within this guarantee Thi...

Page 9: ...vice personnel in parts repair 32 Guidance and manufacture s declaration electromagnetic emission Emission test RF emission Harmonic Voltage Group 1 Class B Not applicable Not applicable The Digital B...

Page 10: ...r in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic...

Reviews: