NTI VOPEX SERIES SPLITTER/EXTENDER
3
LIMITATIONS
•
The audio input of the VOPEX-C5VA-xC1000 is compatible with the following standard CPU audio outputs:
•
Line out - typically lime green in color
•
Speaker out- typically orange in color
•
Headphone out
•
The audio outputs of the VOPEX and the XTENDEX Receiver are compatible with self-powered stereo speakers.
PREPARATION FOR INSTALLATION
•
Locations should be chosen for the monitors and speakers that also have space to connect the VOPEX and XTENDEX
Remote Units within the distance provided by the cables. If extension cables are needed, contact NTI for the cables
required.
•
The CAT5 cables must be run to the locations where the VOPEX and XTENDEX Remote Units will be connected. Be
careful to route the cables away from any sources of magnetic fields or electrical interference that might reduce the
quality of the video signal (i.e. AC motors, welding equipment, etc.).
NOTE
: If CAT5 cable is already installed in the
wall and there are RJ45 wall outlets, it will be necessary to obtain male-to-male straight through connection cables long
enough to reach from the wall outlets to the connection locations of the VOPEX and XTENDEX Receivers.
•
A properly grounded, polarized, and preferably surge-protected 120V or 240V electrical outlet (depending on the AC
adapter being used) must be installed close enough to the connection location of the VOPEX and XTENDEX Receivers,
monitors, stereo speakers, and CPU to plug them into.
•
All cables should be installed in such a way that they do not cause stress on their connections to the equipment.
Extended lengths of cable hanging from a connection may interfere with the quality of that connection. Secure cables
as needed to minimize this.
•
Properly shut down and disconnect the power from all devices to be separated. If other equipment is involved whose
connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper disconnection
and re-connection procedures before proceeding.
Note: CAT5 connection cable used between NTI VOPEX and XTENDEX Series Remote or any XTENDEX Series
products should not be run underground, outdoors or between buildings.
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
Up to 600 feet of CAT5 cable can be installed between the VOPEX and any ST-C5V(A)-R-600 or ST-C5V(A)X2-R-600
Remote Unit.
Up to 1000 feet of CAT5 cable can be installed between the VOPEX and any ST-C5V(2A)-R-1000SP Remote Unit.
Use the charts on page 13 to determine what length of cable can be used for the desired resolution.
!