NTI VOPEX SERIES SPLITTER/EXTENDER
14
ST-C5VA-R-600 Remote Units
Distances and Maximum Supported Resolutions for CAT5, CAT5e and CAT6 Cables
CABLE
DISTANCE (feet)
RESOLUTION
CAT5/CAT5e (UTP)
600
1024x768 at 60Hz
CAT5/CAT5e (UTP)
400
1280x1024 at 60Hz
CAT5/CAT5e (UTP)
300
1600x1200 at 60Hz
CAT5/CAT5e (UTP)
100
1920x1440 at 60Hz
CAT6 (UTP)
300
1024x768 at 60Hz
CAT6 (UTP)
200
1280x1024 at 60Hz
CAT6 (UTP)
100
1920x1440 at 60Hz
INTERCONNECTION CABLE WIRING METHOD
The connection cable between the VOPEX and each XTENDEX Receiver is terminated with either RJ45 connectors or M12
connectors (see installation instruction for you model) and must be wired according to the EIA/TIA 568B industry standard.
Wiring is as per the tables and drawings below.
RJ45 Connector Wiring
Pin
Wire Color
Pair
Function
1
White/Orange
2
T
2
Orange
2
R
3
White/Green
3
T
4
Blue 1
R
5
White/Blue
1
T
6
Green 3
R
7
White/Brown
4
T
8
Brown 4
R
Figure 9- View looking into RJ45 female
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series
products should not be run underground, outdoors or between buildings.
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
T
1
+
R
2
-
T
3
+
R
4
-
T
5
+
R
6
-
T
7
+
R
8
-
Pair 2
Pair 1
Pair 4
Pair 3
!