NTI UNIMUX MULTI-USER KVM SWITCH
47
SX-
Examine connections
Command:
Byte 1
Byte 2
Byte 3
‘S’
(0x53)
‘X’
(0x58)
<CR>
(0x0D)
Response:
Multiple lines, one line for each output:
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
‘p’
(0x70)
‘c’
(0x63)
Space
(0x20)
Output
–
1st digit
(0x30
…
0x32)
Output
–
2nd digit
(0x30
…
0x39)
‘:’
(0x3A)
Input
–
1st digit
(0x30
…
0x32)
Input
–
2nd digit
(0x30
…
0x39)
<CR>
(0x0D)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
‘p’
(0x70)
‘c’
(0x63)
Space
(0x20)
Output
–
1st digit
(0x30
…
0x32)
Output
–
2nd digit
(0x30
…
0x39)
‘:’
(0x3A)
Input
–
1st digit
(0x30
…
0x32)
Input
–
2nd digit
(0x30
…
0x39)
<CR>
(0x0D)
Last line:
Byte 1
Byte 2
‘
∗
’
(0x2A)
<CR>
(0x0D)
CC-
Save connection configuration into permanent memory at given location
Command:
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
‘C’
(0x43)
‘C’
(0x43)
Space
(0x20)
Location
–
1st digit
(0x30
…
0x32)
Location - 2nd digit
(0x30
…
0x39)
<CR>
(0x0D)
Response:
Byte 1
Byte 2
‘
∗
’
(0x2A)
<CR>
(0x0D)
This command saves the current connection configuration into permanent memory for further use. Up to 100 configurations can
be stored
RC-
Read connection configuration from permanent memory at given location
Command:
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
‘R’
(0x52)
‘C’
(0x43)
Space
(0x20)
Location
–
1st digit
(0x30
…
0x32)
Location - 2nd digit
(0x30
…
0x39)
<CR>
(0x0D)
Response:
Byte 1
Byte 2
‘
∗
’
(0x2A)
<CR>
(0x0D)
This command loads the connection configuration from permanent memory into current configuration. Up to 100 configurations
can be stored