background image

Controller Series E1000/2000/4000  

NTI AG  

Installation: E1000/E2000/E4000 series / 16.09.2005 

Page 10/12 

 

 

 

E1000 

Single axes controller 

E2000 

2 axes controller

 

E4000 

4 axes controller

 

Width 

mm (in) 

90 (3.5) 

Height 

mm (in) 

330 (13) 

Height without fixings 

mm (in) 

295 (11.9) 

Depth 

mm (in) 

176 (7) 

Weight 

Kg (lb) 

2.5 (5.5) 

2.6 (5.7) 

2.7 (5.9) 

Case  

IP 

40 

Storage Temperature 

°C -25…70 

Operating Temperature 

°C 0…50 

Max. Case Temperature 

°C 65 

 
 

Power Supply Requirement  

 

Power Supply motor 

The calculation of the needed power for the Motor supply is depending on the application and the used motor(s). 
The following table shows a recommendation for general applications. 
 

Controller   

Voltage/ Power 

LinMot Switched- Power Supply   Part-Nr. 

E1000 

1 motor 

72 V / 300 W 

S01-72/300 

0150-1942 

E2000 

Up to 2 motors 

72 V / 600 W 

S01-72/600 

0150-1943 

E4000 

Up to 4 motors 

72 V / 600 W 

S01-72/600 

0150-1943 

  

Power Supply signal 

24 … 48 V  / 10 W 
 

 

Regeneration of Power 

The Exxxx controller don’t use a regeneration resistor. In most application the recuperated energy will not become 
an issue. In cases where the motor power supply voltage will exceeds the voltage limits because of recuperation 
an additional capacitor between ‘PWR motor’ and ‘GND’ should be used. Typical: 22’000 uF.   

 

 
 

Ordering Information 

 

Servo Controller 

Description 

Art. No. 

E1000-AT 

Analog Trigger Controller 1 Axis (72V/6A) 

0150-1605 

E1000-MT 

Multi Trigger    Controller 1 Axis (72V/6A) 

0150-1615 

E1000-DN 

DeviceNet        Controller 1 Axis (72V/6A) 

0150-1645 

E1000-CO 

CanOpen         Controller 1 Axis (72V/6A)) 

0150-1673 

 

 

 

E2000-AT 

Analog Trigger Controller 2 Axis (72V/6A) 

0150-1606 

E2000-MT 

Multi Trigger    Controller 2 Axis (72V/6A) 

0150-1616 

E2000-DN 

DeviceNet        Controller 2 Axis (72V/6A)) 

0150-1646 

E2000-CO 

CanOpen         Controller 2 Axis (72V/6A)) 

0150-1674 

 

 

 

E4000-AT 

Analog Trigger Controller 4 Axis (72V/6A) 

0150-1608 

E4000-MT 

Multi Trigger    Controller 4 Axis (72V/6A) 

0150-1618 

E4000-DN 

DeviceNet        Controller 4 Axis (72V/6A) 

0150-1648 

E4000-CO 

CanOpen         Controller 4 Axis (72V/6A) 

0150-1676 

 

Summary of Contents for LinMot E1000 Series

Page 1: ...O E2000 AT MT DN CO E4000 AT MT DN CO Content IMPORTANT NOTES FOR E1000 E2000 E4000 SERIES CONTROLLERS 2 SYSTEM OVERVIEW 3 E1000 SERIES FUNCTION AND WIRING 4 POWER SUPPLY AND GROUNDING 5 DESCRIPTION O...

Page 2: ...llers Do not switch Power Supply DC Voltage All power supply switching and E Stop breaks should be done to the AC supply voltage of the power supply Do not connect or disconnect the motors from contro...

Page 3: ...ower Supply Motor 48 72 V From AC Mains 1x115V AC 1x230V AC RS232 Interface to PC for Configuration Linear Motor with internal Position Feedback Power Supply Signal 24 48 V Interfaces to PLC or PC Int...

Page 4: ...Fuse Emergency Stop Breaker 48 72VDC Power Supply motor PWR motor GND 10 AT 0 5 AT signal components 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5 4 3 2 1 9 8 7 6 1 11 Emergency Stop 6 1 7 2 12 8 3 13 14 15...

Page 5: ...n order to assure a safe and error free operation and to avoid severe damage to system components all system components must be well grounded to either a single earth or utility ground This includes b...

Page 6: ...Supply voltage for PWR Signal and PWR Motor may be different Motor Supply GND must be externally connected to earth Caution By exceeding 53VDC Power Supply Signal the controller will go into error st...

Page 7: ...s by your own double check motor wiring carefully before power up Do not connect or disconnect the motors from controllers with voltage present Wait to connect or dis connect motors until all LinMot c...

Page 8: ...put resistance 100kOhm for logical zero 2V for logical one 3 5V Dig Outputs Dig Out 6 Pos Error Out MSG Error Out Warn Out Dig Out 5 Open Collector max 24V 50 mA Typical pull up Resistor R for V 5V su...

Page 9: ...es 16 09 2005 Page 9 12 Mechanical Dimension Dimensions 295 64 90 330 179 Centers 315 Fixings for 2 x M5 screws Recommended mounting for multiple controller installation Fixings for 2 x M5 screws LinM...

Page 10: ...8 V 10 W Regeneration of Power The Exxxx controller don t use a regeneration resistor In most application the recuperated energy will not become an issue In cases where the motor power supply voltage...

Page 11: ...e mounted and used in strict accordance with the installation instruction contained within the User s Manual a copy of which may be obtained from NTI Ltd I declare that as the authorized representativ...

Page 12: ...supply voltage for the Power circuitry is too low 3x l l l l The supply voltage for the Power circuitry is too high 4x l l l l The supply voltage for the Signal circuitry is too low 5x l l l l The sup...