Important notes for E1000/E2000/E4000 series controllers 

 

CAUTION !! 

 
 
 

 
 In order to assure a safe and error free operation, and to avoid 
severe damage to system components, all system components 
must be directly attached to a single ground bus that is earth or 
utility grounded. 
 
 
Each system component should be tied directly to the ground bus 
(star pattern), rather than daisy chaining from component to 
component. (LinMot motors are properly grounded through their 
power cables when connected to LinMot controllers.) 
 
 
All connectors must not be connected or disconnected while DC 
voltage is present. Do not disconnect system components until all 
LinMot controller LED’s have turned off. (Capacitors in the power 
supply may not fully discharge for several minutes after input 
voltage been disconnected). Failure to observe these precautions 
may result in severe damage to electronic components in LinMot 
motors and/or controllers.   
 
 
Do not switch Power Supply DC Voltage. All power supply switching 
and E-Stop breaks should be done to the AC supply voltage of the 
power supply.  
 
 
Do not connect or disconnect the motors from controllers with 
voltage present. Wait to connect or disconnect motors until all 
LinMot controller LED’s have turned off. (Capacitors may not fully 
discharge for several minutes after power has been turned off). 
Failure to observe these precautions may result in severe damage 
to electronic components in LinMot motors and/or controllers. 
 

© 2004 NTI Ltd 
This work is protected by copyright. 
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including 
photocopying, recording, microfilm, storing in an information retrieval system, not even for didactical use, or translating, in whole 
or in part, without the prior written consent of NTI AG. 
 
LinMot® is a registered trademark of NTI AG. 
 
Note 
The information in this documentation reflects the stage of development at the time of press and is therefore without obligation. 
NTI AG. reserves itself the right to make changes at any time and without notice to reflect further technical advance or product 
improvement.

 

Summary of Contents for LinMot E1000 Series

Page 1: ...O E2000 AT MT DN CO E4000 AT MT DN CO Content IMPORTANT NOTES FOR E1000 E2000 E4000 SERIES CONTROLLERS 2 SYSTEM OVERVIEW 3 E1000 SERIES FUNCTION AND WIRING 4 POWER SUPPLY AND GROUNDING 5 DESCRIPTION O...

Page 2: ...llers Do not switch Power Supply DC Voltage All power supply switching and E Stop breaks should be done to the AC supply voltage of the power supply Do not connect or disconnect the motors from contro...

Page 3: ...ower Supply Motor 48 72 V From AC Mains 1x115V AC 1x230V AC RS232 Interface to PC for Configuration Linear Motor with internal Position Feedback Power Supply Signal 24 48 V Interfaces to PLC or PC Int...

Page 4: ...Fuse Emergency Stop Breaker 48 72VDC Power Supply motor PWR motor GND 10 AT 0 5 AT signal components 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5 4 3 2 1 9 8 7 6 1 11 Emergency Stop 6 1 7 2 12 8 3 13 14 15...

Page 5: ...n order to assure a safe and error free operation and to avoid severe damage to system components all system components must be well grounded to either a single earth or utility ground This includes b...

Page 6: ...Supply voltage for PWR Signal and PWR Motor may be different Motor Supply GND must be externally connected to earth Caution By exceeding 53VDC Power Supply Signal the controller will go into error st...

Page 7: ...s by your own double check motor wiring carefully before power up Do not connect or disconnect the motors from controllers with voltage present Wait to connect or dis connect motors until all LinMot c...

Page 8: ...put resistance 100kOhm for logical zero 2V for logical one 3 5V Dig Outputs Dig Out 6 Pos Error Out MSG Error Out Warn Out Dig Out 5 Open Collector max 24V 50 mA Typical pull up Resistor R for V 5V su...

Page 9: ...es 16 09 2005 Page 9 12 Mechanical Dimension Dimensions 295 64 90 330 179 Centers 315 Fixings for 2 x M5 screws Recommended mounting for multiple controller installation Fixings for 2 x M5 screws LinM...

Page 10: ...8 V 10 W Regeneration of Power The Exxxx controller don t use a regeneration resistor In most application the recuperated energy will not become an issue In cases where the motor power supply voltage...

Page 11: ...e mounted and used in strict accordance with the installation instruction contained within the User s Manual a copy of which may be obtained from NTI Ltd I declare that as the authorized representativ...

Page 12: ...supply voltage for the Power circuitry is too low 3x l l l l The supply voltage for the Power circuitry is too high 4x l l l l The supply voltage for the Signal circuitry is too low 5x l l l l The sup...

Reviews: