NTI AG LinMot E1000 Series Installation Manual Download Page 7

Controller Series E1000/2000/4000  

NTI AG  

Installation: E1000/E2000/E4000 series / 16.09.2005 

Page 7/12 

Mot A (B,C,D) 

Motor Connector 

 

 

10

1

 

 

 

 

Cosine

Sine

A

GND

+5VDC

Phase 2-

Phase 2+ 

Phase 1-   

Phase 1+  

2k2

2k2

10k

T

emp

.

+5VDC

black

green

yellow

inner shield

grey

blue

pink

white

red

Outer shield connected

GND GND

+5VDC

Mot A (B,C,D)

GND

Extension Cable

2

1

3 4

7

6

5

8 9 10

 

 Note: 

- Use only special double-shielded Linear Motor Cable (see datasheet ‘extension cables’)  
- Use +5V (Pin 3) and AGND (Pin 6) only for motor internal Hall Sensor supply (max. 100mA). 
- Do NOT connect AGND (Pin 6) to ground or earth! 
- Inner shield (AGND) and outer shield (earth) must be isolated to each other. 
 
Caution: 
- Wrong Motor wiring may damage Linear Motors and/or Servo Controller.  
- If you are assembling motor cables by your own, double check motor wiring carefully before power 
up. 

Do not connect or disconnect the motors from controllers with voltage present. Wait to connect or dis-
connect motors until all LinMot controller LED’s have turned off. (Capacitors may not fully discharge for 
several minutes after power has been turned off).Failure to observe these precautions may result in 
severe damage to electronic components in LinMot motors and/or controllers. Depending on the 
environment the outer shield of the motor cable should be directly connected to the control cabinet 
where the controller is built in to get the best emc results. 
  

Com 

COM  (RS-232, RS-485, CAN) 

5

4

3

2

1

9

8

7

6

 

DSUB-9 (male) 

 

ID high

ID low

 

 

ID for RS485 and CAN 

(Controller from the bottom) 

 

 

GND

GND

6

1

2

7

4

8

3

9

5

RS-232 TX

1k0

RS-232 RX

CAN L

CAN H

RS-485 Y 

(TX+)

RS-485 A (RX+)

RS-485 B (RX-)

RS-485 Z (Tx-)

 

 RS232:  9.6kBaud, use 1:1 connection cable to PC 

RS485 and CAN needs external termination (see manual) 

Summary of Contents for LinMot E1000 Series

Page 1: ...O E2000 AT MT DN CO E4000 AT MT DN CO Content IMPORTANT NOTES FOR E1000 E2000 E4000 SERIES CONTROLLERS 2 SYSTEM OVERVIEW 3 E1000 SERIES FUNCTION AND WIRING 4 POWER SUPPLY AND GROUNDING 5 DESCRIPTION O...

Page 2: ...llers Do not switch Power Supply DC Voltage All power supply switching and E Stop breaks should be done to the AC supply voltage of the power supply Do not connect or disconnect the motors from contro...

Page 3: ...ower Supply Motor 48 72 V From AC Mains 1x115V AC 1x230V AC RS232 Interface to PC for Configuration Linear Motor with internal Position Feedback Power Supply Signal 24 48 V Interfaces to PLC or PC Int...

Page 4: ...Fuse Emergency Stop Breaker 48 72VDC Power Supply motor PWR motor GND 10 AT 0 5 AT signal components 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5 4 3 2 1 9 8 7 6 1 11 Emergency Stop 6 1 7 2 12 8 3 13 14 15...

Page 5: ...n order to assure a safe and error free operation and to avoid severe damage to system components all system components must be well grounded to either a single earth or utility ground This includes b...

Page 6: ...Supply voltage for PWR Signal and PWR Motor may be different Motor Supply GND must be externally connected to earth Caution By exceeding 53VDC Power Supply Signal the controller will go into error st...

Page 7: ...s by your own double check motor wiring carefully before power up Do not connect or disconnect the motors from controllers with voltage present Wait to connect or dis connect motors until all LinMot c...

Page 8: ...put resistance 100kOhm for logical zero 2V for logical one 3 5V Dig Outputs Dig Out 6 Pos Error Out MSG Error Out Warn Out Dig Out 5 Open Collector max 24V 50 mA Typical pull up Resistor R for V 5V su...

Page 9: ...es 16 09 2005 Page 9 12 Mechanical Dimension Dimensions 295 64 90 330 179 Centers 315 Fixings for 2 x M5 screws Recommended mounting for multiple controller installation Fixings for 2 x M5 screws LinM...

Page 10: ...8 V 10 W Regeneration of Power The Exxxx controller don t use a regeneration resistor In most application the recuperated energy will not become an issue In cases where the motor power supply voltage...

Page 11: ...e mounted and used in strict accordance with the installation instruction contained within the User s Manual a copy of which may be obtained from NTI Ltd I declare that as the authorized representativ...

Page 12: ...supply voltage for the Power circuitry is too low 3x l l l l The supply voltage for the Power circuitry is too high 4x l l l l The supply voltage for the Signal circuitry is too low 5x l l l l The sup...

Reviews: