Chapter 4 - Managing and Monitoring
Updating Controller Firmware
52
This process takes you to what is called the “Monitor mode.” Once in
Monitor mode (command prompt displayed), type “rs” and press <Enter>.
This will restart the controller using the corrected baud rate.
8
If the menu system does not automatically appear after the controller has
completed its boot cycle, at the screen cursor type <Control-E>. Then type
<Control-W> to switch the interface to the menu-based mode.
9
From the Main menu, select the
Diagnostics Menu
and press <Enter>.
Diagnostics Menu Screen
10
Use the <Up> and <Down> Arrow keys to select
Online Diagnostics
and
press <Enter>.
Online Diagnostics Menu Screen