background image

ID number codes / dipswitch settings

ID number

12345678

ID number

12345678

 ID number

 12345678 

0

00000000

1

10000000

2

 01000000

3

11000000

4

00100000

5

 10100000

6

01100000

7

11100000

8

 00010000

9

10010000

10

01010000

11

 11010000

12

00110000

13

10110000

14

 01110000

15

11110000

16

00001000

17

 10001000

18

01001000

19

11001000

20

 00101000

21

10101000

22

01101000

23

 11101000

24

00011000

25

10011000

26

 01011000

27

11011000

28

00111000

29

 10111000

30

01111000

31

11111000

32

 00000100

33

10000100

34

01000100

35

 11000100

36

00100100

37

10100100

38

 01100100

39

11100100

40

00010100

41

 10010100

42

01010100

43

11010100

44

 00110100

45

10110100

46

01110100

47

 11110100

48

00001100

49

10001100

50

 01001100

51

11001100

52

00101100

53

 10101100

54

01101100

55

11101100

56

 00011100

57

10011100

58

01011100

59

 11011100

60

00111100

61

10111100

62

 01111100

63

11111100

64

00000010

65

 10000010

66

01000010

67

11000010

68

 00100010

69

10100010

70

01100010

71

 11100010

72

00010010

73

10010010

74

 01010010

75

11010010

76

00110010

77

 10110010

78

01110010

79

11110010

80

 00001010

81

10001010

82

01001010

83

 11001010

84

00101010

85

10101010

86

 01101010

87

11101010

88

00011010

89

 10011010

90

01011010

91

11011010

92

 00111010

93

10111010

94

01111010

95

 11111010

96

00000110

97

10000110

98

 01000110

99

11000110

100

00100110

101

 10100110

102

01100110

103

11100110

104

 00010110

105

10010110

106

01010110

107

 11010110

108

00110110

109

10110110

110

 01110110

111

11110110

112

00001110

113

 10001110

114

01001110

115

11001110

116

 00101110

117

10101110

118

01101110

119

 11101110

120

00011110

121

10011110

122

 01011110

123

11011110

124

00111110

125

 10111110

126

01111110

127

11111110

For channels 129 - 256 Set dipswitch 1-7 as above and set dipswitch #8 on.

REMOTE CONTROL PANEL

PROGRAMMING

Software Revision 3.00, Version C

ID number codes / dipswitch settings

NSI CORPORATION

6

Summary of Contents for 804CP

Page 1: ...easy to operate Remote lockout capability is also included Installation is a snap with the simple 4 wire digital connection required IMPORTANT Programming differs from other Luma net panels please read instructions Programming of dimmer channels beyond factory defaults requires computer and software interface package Luma net control panels with software release 3 00 and higher are not directly co...

Page 2: ... in any standard double gang electrical box while the 808CP will mount in a large three gang box with the 4 screws provided See below paragraph on system turn on before final mounting of panels SYSTEM TURN ON It is very important that the system operation be verified one panel at a time Else an improper connection at one panel would cause the entire system to not operate properly and may be diffic...

Page 3: ... the network Steady on or Slow flashing Network trying to reconfigure bad ID While programming the following actions are normal Quickly flashing Programming mode LOCKOUT Any 804CP and 808CP may be disabled from operation with a remote key switch or other contact closure Several Luma net panels of the same version may be connected to the same contacts in parallel as long as polarity is maintained C...

Page 4: ... 8 full ALL OFF button levels Zone 1 4 1 8 off The installer may reprogram the PRESET and ALL OFF buttons easily without additional equipment Other features such as dimmer channel assignment and fade time require a computer and software Details on programming other features are supplied with the Luma net Software Package Optionally the unit may be ordered preprogrammed from the factory REMOTE CONT...

Page 5: ...ave a unique network ID number If two panels have the same network ID number the entire network will stop functioning Panels need not be in program mode to change network ID number since a dipwitch is used To set Network ID number 1 Locate dipswitch on rear of unit as illustrated below 2 Set the switches as per the chart on the following page Factory Default Setting The 804CP and 808CP are program...

Page 6: ...10111100 62 01111100 63 11111100 64 00000010 65 10000010 66 01000010 67 11000010 68 00100010 69 10100010 70 01100010 71 11100010 72 00010010 73 10010010 74 01010010 75 11010010 76 00110010 77 10110010 78 01110010 79 11110010 80 00001010 81 10001010 82 01001010 83 11001010 84 00101010 85 10101010 86 01101010 87 11101010 88 00011010 89 10011010 90 01011010 91 11011010 92 00111010 93 10111010 94 0111...

Page 7: ...ll zones of this panel to fade to the current settings of the slide controls All zone LEDs will come on and the slide controls will have full control PRESET button This button will cause all dimmer channels assigned to all zones of this panel to fade to the zone setting previously programmed Default is all full on All zone LEDs will go out ALL OFF button This button will cause all dimmer channels ...

Page 8: ...epair or replace at its option defective materials provided you have identified yourself as the original owner of the product to NSI or any authorized NSI dealer Transportation charges to and from an authorized dealer or the NSI factory for repair shall be the responsibility of the owner All products returned to NSI must have factory authorization for return prior to shipping NSI Corporation is no...