National Rejectors, Inc. GmbH, Buxtehude
G-13.6 Description of the variants
With each inserted coin the credit is increased by the corresponding
value. The current credit can be displayed.
The lower switch arrangement is used to define the amount of credit at
which the time unit starts (see fig. 3).
e.g.:
lowest coin = 0.10 DM / adjusted multiplier = 20 (4 + 16)
∅
amount of credit for the start = 2.00 DM
Fig. 3: Adjusting the amount of credit for the start
As soon as the credit adjusted with switch block 2 has been
exceeded, the display will stop showing the credit but will instead
show the time unit. A flashing point indicates the running time.
Simultaneously the functional line 1 is triggered. It remains activated
during the whole time.
If the line for total blocking has not been activated it is still possible to
insert further coins. The time on the display is increased
correspondingly.
Functional line 2 is additionally activated when the last time unit is
running. This signal can be used for a warning sound. When the time
has run out this is indicated in the display. The functional lines 1 and 2
are deactivated.
From the machine the time counting can always be interrupted (high
signal) or started (low signal) via line 8 (reset line) .
The remaining credit is displayed when pressing the return button.
1
1
2
2
3
4
4
8
Switch block 2
5
16
6
32
7
64
8
128
ON
OFF
Value