13
National Rejectors, Inc. GmbH, Buxtehude
G-13.6 Description of the variants
•
Variant B:
Multiple sales - type 1
– The remaining credit remains valid after the first price has been
erased.
– Multiple sales are possible.
– Only the first price can be used.
– The second switch is set to the free sales mode.
•
Variant C:
Multiple sales - type 2
– The remaining credit is erased after 2 minutes. When inserting a
further coin in this period the erasing procedure is cancelled.
– Only the first price can be used.
– The second switch is set to the free sales mode.
Timer variant
The timer function means that the credit is erased or a functional line
is deactivated after a pre-set time.
The time unit is normally set to 60 sec., but it can be adjusted by NRI
to any value between 1 and 255.
The time unit is determined by the value of the inserted coin. Use the
upper switch arrangement to define how much a time period costs
(see fig. 2).
e. g.:
lowest coin = 0.10 DM / adjusted multiplier = 10 (2 + 8)
∅
price/min. = 1.00 DM
Fig. 2: Setting the price for one time unit
1
1
2
2
3
4
4
8
Switch block 1
5
16
6
32
7
64
8
128
ON
OFF
Value