STARTING THE DEVICE
NVR
–
3408POE-H2 and NVR-3416
Connect the cable end from the 12 V DC power supply supplied with NVR into socket labelled DC
12V in NVR. In order to supply electricity into PoE ports, cable end from the 48 VDC power supply
must be connected to the socket marked DC48 in NVR. Connect power supply to the mains and set
power switch to “
-
” position to start the device. Wait about two minutes till initialization process ends
and start working with NVR. If you turn off NVR using SHUTDOWN button use ON/OFF button form
front panel to turn on the device.
CAUTION:
Make connection when the power is not applied.
Make sure that power adapter is placed near of NVR and secured from accidental disconnection.
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
STARTING THE DEVICE
DC 48V
ON/OFF
SWITCH
DC 12V