background image

TagTemp-S 

NOVUS AUTOMATION 

5/11

 

5.2.3

 

Events Screen 

 

Fig. 08 – Events Screen 

 

High  excursions: Indicates when the measured value has 

exceeded the maximum upper limit specified for the range. 

  First occurrence: The time of the first event, the measured value 

exceeded the maximum limit. 

  Last occurrence: The time of the last event, the measured value 

exceeded the maximum limit. 

  Total logs within occurrences: Number of acquisitions above 

the maximum range limit. 

  Average temperature within  occurrences: Average value of 

temperatures above the maximum limit. 

 

Low excursions: Indicates when the measured value was below 

the specified lower limit for the range. 

  First occurrence: The time of the first event, the measured value 

was below the minimum limit. 

  Last  occurrence: The time from the last event the measured 

value was below the minimum limit. 

  Total logs within  occurrences: Number of acquisitions below 

the minimum range limit. 

  Average temperature within  occurrences: Average value of 

temperatures below the minimum limit. 

5.2.3.1

 

Event Screen 

Selecting the "See All" option shows the high and low temperature 

events, their respective values and timetables. See examples in the 

images shown in Fig. 10 and Fig. 11
If no high or low events occurred, the messages in Fig. 12 and Fig. 13 

will appear. 

 

Fig. 09 – High Temperature Event Display 

  

 

Fig. 10 – Low Temperature Excursion display 

 

Fig. 11 – High excursions Message "No occurrences"  

Summary of Contents for 8813800000

Page 1: ...ick it over the identification tag Another way is to use the blister hole to attach the transmitter 3 TECHNICAL FEATURES Operating temperature 30 C to 60 C Storage temperature From 30 C to 65 C Measuring range Temperature 30 0 C to 60 0 C Accuracy of measurement 1 C max over the full measuring range Note You can correct the measurement error in the OFFSET parameter using the configuration software...

Page 2: ...on located on the front of the product can be used to start or stop data logging according to the settings To give the command to start or stop logs press this button until the LED turns on and then release it before it goes out If the LED goes off before releasing the button the command will not be validated and the button will be disabled for 30 seconds This is a protective measure to prevent ac...

Page 3: ... about TagTemp S Log interval Indicates the value defined of the interval between each acquisition Loggings Number of records made by TagTemp S Logging state Indicates whether the log is running stopped or waiting for loggings to start Start Delay Memory usage Indicates the memory usage mode full or circular Battery Indicates the status of the battery charge Good Perfect to use Medium Significant ...

Page 4: ...ption you can start logging data by pressing the logger button Stop loggings by button When you enable this option you can stop logging by pressing the logger button Enable circular memory When this option is enabled when the memory is complete the recording will continue overwriting the oldest records Use Fahrenheit degrees when this option is enabled the temperature unit of Celsius default is ch...

Page 5: ...below the specified lower limit for the range First occurrence The time of the first event the measured value was below the minimum limit Last occurrence The time from the last event the measured value was below the minimum limit Total logs within occurrences Number of acquisitions below the minimum range limit Average temperature within occurrences Average value of temperatures below the minimum ...

Page 6: ...the last 2000 To select a graph display range the Chart range option can be used 5 2 4 1 Data Chart Options Screen When you select the icon in the upper right of the screen the chart options will appear Fig 14 Data Chart Options screen 1 By pressing the icon you can share the obtained data using the applications already installed in the smartphone or through the option of publishing in the NOVUS C...

Page 7: ... is read from the device the subsequent changes will not be considered Export to Nx Software NXD Shares a file with the collected data in a format compatible with Nx Software nxd so that the data can be read and displayed by this application Initial screen selection Allows you to select the startup screen after reading the data from the device NOVUS Cloud Authentication Hire an account in the NOVU...

Page 8: ... The Configuration File option is used to read an existing configuration file The reading of the device is done by choosing the option Read the Device If the machine is logging data the following message will be displayed Fig 24 Reading Device Screen Stop logging This option stops data logging and is read allowing the device to be configured Show Only By choosing this option you can only view the ...

Page 9: ...est records will be overwritten with the new values Fig 28 Finalization Screen The Finalization screen is where the configuration settings are sent and allows you to perform some other useful functions Send Configuration Selecting this option will send the settings made for the connected device Save to File This option allows you to save the configuration settings made to a file so it can be reuse...

Page 10: ...the transfer The transfer time will be proportional to the number of acquisitions recorded Viewing Collected Data After the transfer of the records the data collected are presented graphically as shown in the images below 6 4 1 Sharing and processing data After completing the collection a screen will be displayed with the collected data and these are presented in two forms in graph form and table ...

Page 11: ...hart Properties 8 Reports and Data Export 9 Formulas 10 Sending data to NOVUS Cloud 11 Exit 6 5 Exporting and creating reports with the data collected Using the NX Software you can export the collected data to various file formats or create reports from the available templates These two features are accessed by clicking the Reports button in the function menu Export Selecting this option from the ...

Reviews: