background image

 

NOVUS AUTOMATION 

1/6 

 

 

 

 

 

TagTemp-USB 

TEMPERATURE LOGGER –  INSTRUCTIONS  MANUAL 

V1.0x E 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

CE Mark 

This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take 

adequate measures. 

 

Summary of Contents for TagTemp-USB

Page 1: ...agTemp USB TEMPERATURE LOGGER INSTRUCTIONS MANUAL V1 0x E CE Mark This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures ...

Page 2: ...ion and is performing logs in memory 2 TECHNICAL DATA Measure Range Temperature 20 0 C to 70 0 C Accuracy 0 5 C 25 ºC 1 C max along the entire measured range Note A measure error can be fixed using the OFFSET parameter in the LogChart II software Measurement Resolutions Temperature 0 1 C Memory capacity 32 000 32 k logs Measurement Interval 5 seconds min 18 hours max Supply 3 0 V lithium battery C...

Page 3: ...e device Fig 05 Configuration window Fields are 1 Title In this field the user identifies the device by assigning it a name 2 General information Area with information about the device such as Model Serial Number Data Logger Date Hour Actual Date Hour Firmware Version Memory Capacity and Number of acquisitions stored in memory In this field time is constantly updated while the communication betwee...

Page 4: ...ation by the user The Pause Resume button action sends the appropriate command depending on the current registration status If the records are In Progress and pressing this button it will be send a command to Pause the records Pause Pauses the registry allowing it to be resumed later using the Resume button If registration is Paused and pressing this button it will be send a command to Resume the ...

Page 5: ...n can be displayed by pressing the icon Parameter Viewing Fig 09 General information window 5 3 EXPORTING DATA Downloaded data can be exported to different file formats for further analysis To export access File Export or click the icon 5 4 DIAGNOSTICS Battery Level Indicates the level of battery voltage When the battery reaches a low level voltage immediate replacement is recommended to ensure th...

Page 6: ...e device fails Make sure the COM port is selected correctly and there is no other program using the same port during communication attempts Make sure there is no physical obstacle blocking the infrared signal Make sure the cable is well connected to the PC port Make sure the port selected does not present any problem 8 SPECIAL CARE When handling the device and its battery observe the following Whe...