Operating manual
LTSA LTMA
Overview of parameter settings XLP 514 with LTMA
As soon as “LTMA” is selected as peripheral device, the submenus
Options
>
Dispenser
and
Options
>
LTMA
with parameters for setting the dispensing and applicator functions are also displayed.
The submenu
Options
>
Basic I/O Board
appears only if the optional BasicIO board is installed.
Submenu
Parameter
Setting
Mandatory
Options
External signal
Singlestart
X
Options
>
Selection
Periph. device
LTMA
X
Options
>
Basic I/O Board
Start print mode
“Pulse rising” or “Pulse falling”
X
Start source
Foot switch
X
Dispenseposition
0 mm
Dispense Mode
Real 1:1 mode
X
Options
>
Dispenser
Application mode
Immediate mode
Apply mode
After start sig.
Stroke length
190 mm
Appl. waitpos.
0 mm
Applicator speed
350 mm/s
Options
>
LTMA
Restart delay
0 ms
Table 4: List of the most important parameters for applicator operation. The parameters marked “Mandatory” must be set as
shown in order that the applicator functions. The settings for the other parameters are given as recommendations and can be
changed, depending on the application.
Further parameters for integration of the printer into an application with product conveyor and prod-
uct sensor are available in submenu “Dispenser”. In addition, the optional signal interface (BasicIO
board) is necessary for automatic applications for the processing of external start signals.
For further information on parameter settings, refer to the Operating manual XLP 51x, chapter “Pa-
rameter menu”.
Setting the dispensing position (LTSA/LTMA)
For operation of the LTSA/LTMA, the dispensing position should be set so that the label is just dis-
pensed and no longer adheres to the backing material. Advancing of the backing material too far can
result in threads of the adhesive pulling the label down.
Setting:
► Set parameter
Options
>
Dispenser
>
Dispenseposition
to the desired value.
For further details, refer to....
• for XLP 50x: Operating manual XLP 50x or Service manual XLP 50x, chapter “Parameter menu”
• für XLP 51x: Service manual XLP 51x, chapter “Product description” > “Parameter menu”.
3
Only with installed BasicIO board (option). This parameter also influences a connected foot switch.
Edition 02 - 7/2021
23
Commissioning
Settings in the parameter menu