The buttons on the bottom strip allow you to test the printer.
Print grid:
Print test to check if the print head has some broken dots or if the print head and the print plate or
roll are perfectly aligned in the whole print area size. In case of white lines in print direction it means
that some dots are probably broken, or that the print head could be dirty. The current date is also
printed on the grid to highlight the date when the test has been done. So, the operator can have
day by day the status of the print head.
Print lines:
Print test of lines parallel to the print direction. The lines are
parallel to the print direction. This test helps to verify the settling
and the stability of the head on the media during print. In case of
bends it means that the print head support or the head alignment
to the print roll or plate is not in the best condition or that the
support is not stable.
Note:
print grid and lines will be printed with the current label size.
Print current page: press this button to print the current label.
(This button is also accessible through the shortcuts
on the Manual mode view, if you have at least level
1 access. See “Product Description – Operation Panel”)
Figure 57: diagnostic
Yellow = Input ON
Grey = Input OFF
good