60
WAAS G-III Reference Receiver User Manual Rev 1
Chapter 4
Commands
4.4.14
LOG
You can log many different types of data using several different methods of triggering the log events. See
Chapter 5, Data Logs
starting on
Page 85
for further information and a complete list of data log structures.
To remove a log use the
UNLOG
command. To remove all logs, use the
UNLOGALL
command.
The
period
parameter is only valid when the
ONTIME
trigger is being used.
Valid States
:
Configuration, Operational, Maintenance
Valid Modes
: Normal,
Failed
Acceptable Ports
: Data
Syntax:
LOG [port] message [trigger] [period]
Example:
LOG ICOM1 measurementdatab ontime 1
LOG ICOM1 rxcommandsb
LOG versionb
LOG agcinfob once
Field
Field Name
Description
Range
Precision
1
port
The communication port used to output the data.
[Optional].
If a port is not specified, the requested logs are output
on the port from which the command was issued.
ICOM1
ICOM2
N/A
2
message
The message type.
See
Table 24
on Page 61
N/A
3
trigger
The trigger condition.
Select
once
to output the log only once.
Select
onnew
to output the log immediately and each
time it is updated.
Select
ontime
to output the log at the rate specified in
the
period
field.
[Optional]
If the trigger condition is not specified, a default of
once
is used.
once
onnew
ontime
N/A
4
period
Number of seconds between logs
[Optional]
If the trigger condition is
ontime
, and the
period
is not
specified, a default of 1 is used.
1-1000
Int