100
WAAS G-III Reference Receiver User Manual Rev 1
Chapter 5
Data Logs
18
Value 7
IOMaster = 1V5 Supply voltage (V)
DSPC = 1V5 Supply voltage (V)
RFCC 1 = 1V5 Supply voltage (V)
RFCC 2 = 2V5S6 (V)
RFCC 3 = Reserved (0)
RFDC = Reserved (0)
Float
4
H+56
19
Value 8
IOMaster = 1V2 Supply voltage (V)
DSPC = 1V2 Supply voltage (V)
RFCC 1 = 13V0RF (V)
RFCC 2 = 2V5S7 (V)
RFCC 3 = Reserved (0)
RFDC = Reserved (0)
Float
4
H+60
20
Value 9
IOMaster = 1V05 Supply voltage (V)
DSPC = 1V05 Supply voltage (V)
RFCC 1 = 13V0RF_A (A)
RFCC 2 = 2V5S8 (V)
RFCC 3 = Reserved (0)
RFDC = Reserved (0)
Float
4
H+64
21
Value 10
IOMaster = 0V75 Supply voltage (V)
DSPC = 0V75 Supply voltage (V)
RFCC 1 = 9V0A (V)
RFCC 2 = 2V5S9 (V)
RFCC 3 = Reserved (0)
RFDC = Reserved (0)
Float
4
H+68
22
warning word
Warning status word
For information about the warning status word, see:
Table 36, IOMaster Warning Status Word
on
Page
101
Table 37, DSPC Warning Status Word
on
Page 102
Table 38, RFCC Warning Status Word
on
Page 102
Table 39, RFDC Warning Status Word
on
Page 103
Ulong
4
H+72
23
error word
Error status word
For information about the error status word, see:
Table 40, IOMaster Error Status Word
on
Page 104
Table 41, DSPC Error Status Word
on
Page 104
Table 42, RFCC Error Status Word
on
Page 105
Table 43, RFDC Error Status Word
on
Page 106
Ulong
4
H+76
Next entry, offset = H+20 + (# previous cards * 60)
24
#fans
Number of fans to follow.
Ulong
4
H + 20 +
(#cards *
60)
25
Fan speed
Speed of fan (rpm)
Ushort
2
H+20 +
(#cards *
60) +4
26
Fan failed
0 = Okay
1 = Failed
Ushort
2
H+20 +
(#cards *
60) +6
Next entry, offset = H+20 + (#cards * 60) + 4 + (#previous fans * 4)
Field
Field Name
Description
Format # Bytes
Binary
Offset