Chapter 2 Installation of OEM7 Family Receiver Cards
OEM7 Installation and Operation User Manual v4
42
Figure 15: COM3 and USB Multiplexed on OEM719
To enable COM3, issue the following commands:
1.
INTERFACEMODE USB1 NONE NONE
2.
INTERFACEMODE USB2 NONE NONE
3.
INTERFACEMODE USB3 NONE NONE
4.
MARKCONTROL MARK1 DISABLE
5.
INTERFACEMODE COM3 NOVATEL NOVATEL
6.
SAVECONFIG
(optional)
To enable USB, issue the following commands:
1.
INTERFACEMODE COM3 NONE NONE
2.
INTERFACEMODE USB1 NOVATEL NOVATEL
3.
INTERFACEMODE USB2 NOVATEL NOVATEL
4.
INTERFACEMODE USB3 NOVATEL NOVATEL
5.
SAVECONFIG
(optional)
To enable EVENT1, issue the following commands:
1.
INTERFACEMODE COM3 NONE NONE
2.
MARKCONTROL MARK1 ENABLE
3.
SAVECONFIG
(optional)
OEM729 RS-422 Port
On the OEM729 card, COM1 can be configured as either RS-232 (optionally with hardware flow
control, if the cable used supports it) or RS-422 (with no hardware flow control), by setting pin 2