Chapter 2 SPAN Installation
OEM7 SPAN Installation and Operation User Manual v14
58
For information about the OEM7 receiver card connectors and pinouts, refer to the
Use the following steps to install the OEM719 receiver and MIC:
1. Mount the components of the SPAN system. See
Mount the SPAN System Components
2. Connect the IMU to the MIC. See
3. Connect power to the MIC. See
4. Connect the input and output signals to the MIC. See
Connect the Input and Output Signals
Mount the SPAN System Components
1. Mount the antenna. See
2. Use the standoffs supplied with the MIC card to secure the OEM719 to its mounting location.
See
Figure 7: Mount the MIC on the OEM719
See the
OEM7 Installation and Operation User Manual
for information about installing an OEM7 receiver.
The part number for the recommended standoffs is RAF-M21073005AL7 (Irwin
Industrial).
If alternate standoffs are selected, use equivalent parts with a minimum height of 12
mm.
Ensure all standoffs are properly installed and the mounting location is flat.
The amount of board deflection (bow and twist) must not exceed 0.75%. For example, on the
MIC which is 75 mm long and 46 mm wide, the deflection along the length must not exceed
0.56 mm and the deflection along the width must not exceed 0.34 mm.
Ensure the MIC is mounted close enough to the IMU so the interface cable can reach both
devices.
3. Connect the antenna cable to the antenna jack on the OEM719.
The antenna cable must have a right angle MCX connector on the end that connects to the OEM719.
Warning!
Do not apply power to the cards until the antenna cable is attached.
The part number for the recommended MCX connector is M1051-
110 (ShinA Telecom). If an alternate part is used, it should meet the
dimensions shown in the diagram.
The space between the OEM719 and the MIC is limited. The height
of the MCX connector must not exceed 8.65 mm.
4. Align the mating connector (J301) on the MIC with the 20-pin header (P1701) on the OEM719.