APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
144
A.2.3 IMU-CPT Electrical and Environmental
Electrical
Input Power
9 - 18 VDC
Power Consumption
13 W (max)
Power and I/O Connector
MIL-DTL-38999 Series 3
Start-Up Time (Valid Data)
< 5 seconds
Table 39: IMU-CPT Electrical Specifications
Environmental
Temperature, operational
-40°C to +65°C
Temperature, non-operational
-50°C to +80°C
Vibration, operational
6 g rms, 20 Hz -2 KHz
Vibration, non-operational
8 g rms, 20 Hz -2 KHz
Shock, operational
7g 6-10 msec, 1/2 sine
Shock, non-operational
60 g 6-10 msec, 1/2 sine
Altitude
-1000 to 50,000 ft.
Humidity
95% at 35°C, 48 hrs
MTBF
≥ 10,500 hours
Table 40: IMU-CPT Environmental Specifications