APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
198
A.9.2 IMU-µIMU-IC Sensor Specifications
Gyroscope Performance
Input range
±499 °/second
Bias stability
≤6 °/hour
Scale factor error
≤1400 ppm
Angular random walk
≤0.3 °/√hour
Accelerometer Performance
Input range
±15 g
Bias repeatability
≤3 mg
Scale factor error
≤1500 ppm
Velocity random walk
≤0.25 mg/degree/√Hz
Data Rate
IMU Measurement
200 Hz
Table 92: IMU-µIMU-IC IMU Performance