APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
263
Pin
Signal
Type
Description
Comments
6
LED1
Output
Status LED 1 /
IMU Data Status
7
Reserved
N/A
Leave as no
connect
8
DGND
Power
Digital ground
9
Reserved
N/A
Leave as no
connect
10
Reserved
N/A
Leave as no
connect
11
N/C
N/A
12
N/C
N/A
13
USB D-
Bidirectional
USB interface
data (-)
Only available in board stackup with OEM719
In standalone, no connect
14
USB D+/
COM3 RX
Bidirectional
USB interface
data (+)/
COM3 receive
data
Only available in board stackup with OEM719
In standalone, no connect
The USB port is enabled by default and the COM3 port is
disabled by default. If you enable the COM3 port, the USB
port is disabled.
15
RESETIN
Input
OEM719 reset in
Only available in board stackup with OEM719
In standalone, no connect
16
VARF/
CAN1 RX
Output/
Input
Variable
frequency
output/CAN1
receive data
Only available in board stackup with OEM719
In standalone, no connect
The VARF output is enabled by default and the CAN1RX
input is disabled by default. If you disable VARF, the
CAN1RX input is enabled.
17
EVENT2/
CAN1 TX
Input/
Output
Event2 input/
CAN1 transmit
data
Only available in board stackup with OEM719
In standalone, no connect
The Event2 input is enabled by default and the CAN1TX
output is disabled by default. If you disable EVENT2, the
CAN1TX output is enabled.
18
CAN2 RX
Input
CAN2 receive
data
Only available in board stackup with OEM719
In standalone, no connect