1.  GENERAL PROVISIONS 

 

1.1.  BASIC FUNCTIONS 

- microprocessor controlled. 
- simple change-over between sequential and combination timer. 
- 7-segment LED indications. 
- selectable 3 time ranges (SEC:MSEC, MIN:SEC, HRS:MIN) 
- cascade connection of several devices for extended total number of channels. 
- memorization of program and device mode after switching off and program operation restart 
from point of stoppage. 
- inputs for timer start and pause control. 
- fast resetting. 
- copy of settings. 
- program can be executed only one time or/and cyclic operation possible. 
- RS-232 communication port for programming and possibility of operation through PC/ DCS 
(free PC software). 

 
 
 
 

1.2. BASIC TECHNICAL BRIEF 
 

Table 1.1. 

Supply voltage, V  

85 to 270 AC/DC  

Frequency range, Hz  

47-63 

Power consumption, VA  

8  

Time setting range  

From 100ms to 

99hr59min.  

Commutation accuracy  

±0.1% + 20ms  

Number of channels  

15  

Number of combinations per channel (ON/OFF)  

8  

Operating  temperature range, °C  

from -25 t55  

Storage temperature, °С 

 

from -35 t80  

Humidity (non condensing)  

95% @ 40°С 

 

Insulation resistance  

>100МOhm @ 500V 

DC  

Dimensions, mm  

85.8 х 156.2 х 56.8 

 

Indication of load relay  

Yes  

Protection level  

ІР20 

 

Climatic resistance version  

УХЛ4 

 

Data memory, years, minimum  

10  

Output Relays, CO  

15  

Channel contacts type  

normally open 

contact (NO)  

Summary of Contents for TK-415

Page 1: ...TD Sequential and Combination Timer TK 415 with RS 232 communication OPERATION MANUAL WWW NOVATEK ELECTRO COM EN 2011 www novatek electro in 15 channel Traffic Controller TK 415 Sequential cum Combina...

Page 2: ...possible RS 232 communication port for programming and possibility of operation through PC DCS free PC software 1 2 BASIC TECHNICAL BRIEF Table 1 1 Supply voltage V 85 to 270 AC DC Frequency range Hz...

Page 3: ...mum electric resource 4A 250V AC os 0 4 times minimum 107 100 000 30 000 100 000 Signal Start Contact Closure S1 and S2 maximum at 150 milliseconds Mounting onto standard 35 mm DIN rail Mounting posit...

Page 4: ...g to technical specifications 10 RANGE Button for selection of range of time programming DLY ON according to the Table 1 2 Table 1 2 Designation Range HRS MIN from 1 minute to 99 hours 59 minutes MIN...

Page 5: ...e of channel contacts 18 Indicator of selected time range see Table1 2 19 Indicator displaying current mode of time programming of open DLY or closed ON contacts on Time indicator 20 Indicator of sele...

Page 6: ...6 II Sequential timer cycling mode inputs C1 and C2 are not shorted Diagram 1 2...

Page 7: ...7 III Combination timer mode of execution of one cycle of program inputs C1 and C2 are shorted Diagram 1 3 Where for example R2C5 means the fifth combination of the second channel relay...

Page 8: ...8 IV Combination timer cycle mode inputs C1 and C2 are not shorted Diagram 1 4...

Page 9: ...ETTING AND OPERATION 2 1 CONNECTION The Figure 2 1 represents the typical method of timer connection Load is connected to output of channel RLY10 as an example Figure 2 1 Typical method of timer conne...

Page 10: ...rs with possibility of cycle work upon completion of operation of last timer the first one starts operating is represented at Figure 2 3 Figure 2 3 Cycle operation of timers in case of cascade connect...

Page 11: ...nel 1 4 Using button COMBINATION select combination 1 5 Using button DLY ON select time DLY for time setting during which the contacts of channel relay will be open 6 Press RANGE for selection of nece...

Page 12: ...ce see Diagram 1 1 2 9 JOINT OPERATION OF SEVERAL TIMERS IN SEQUENTIOAL MODE In case of cascade connection of several timers outputs O1 and O2 of the first timer should be connected to inputs S1 and S...

Reviews: