background image

QUASAR PROJECT KIT # 3148T9 - PROGRAMMABLE DOWN TIMER (UP TO 99 MIN 59 SEC) 

 

Page 

1

 of 

2

 

 

This is a 4-digit programmable down timer with output and 
reset. The uC is marked 

T9

. Timing is in 

minutes 

and 

seconds 

with a maximum programmable time of 100 

minutes (00.00) which is 1 hour 40 minutes. It has 

five 

operating modes 

that control the output function when the 

timer reaches zero. 

 

HARDWARE SPECIFICATIONS 
Timing range 

00.00 to 99 minutes 59 seconds 
Starting at 00.00 gives 100 
minutes (1h 40m) 

Inputs 

Start, Stop and Reset 
Active low (see text) 

Output 

Open collector NPN transistor, 
100mA @ 30V 

Supply voltage 

9 to 12V DC 

Supply current 

30 to 50mA, depending on the 
number displayed. 

Display 

4-digit 7-segment with decimal 
point, 14mm RED LED 

Physical size 

51mm x 66mm (2.0” x 2.6”) 

Connection 

10-way right-angle SIL header 
pins 0.1” spacing. Male or female 

 

 
PROGRAMMING THE TIMER 

The two buttons marked 

START 

and 

STOP 

are used to 

program the operating time 

(4 digits) first, and 

select the 

operating mode 

(1 digit) second. 

 
The Stop and Start button are also bought out to the SIL 
header for connection to your own switches along with 
Power input, Reset (switch not included) and the Output. 

 

When you apply power, you will see 

00.00 

on the display. 

 

If you press the 

START 

button now you will start to count 

down from 100 min. Do not do that yet. If you did, 
reconnect the power and start again at 

00.00 

 

Programming the countdown time is done 

one digit at a 

time 

starting with the leftmost x10-minutes digit. The 

decimal points are used to indicate which digit to its left is 
being set. 

 

Press the 

STOP 

button once to enter programming mode. 

The leftmost decimal point will come and show 

0.000 

Now 

use the START button to set the value required from 0-9. 
When you have selected the 1st digit you want (say 2) press 
the STOP button and you will see 

20.00. 

The “2” has been 

set and you are now ready to program the minute-units 
digit. Press the START button to set the 2nd digit to say 7. 
Press the STOP. You will see 

270.0 

 

Repeat the steps above for the x10-seconds and Seconds-
units digits. 

 

After you set the units digit and press STOP the display will 

switch to allow the 

operating mode 

to be set. The current 

operating mode, probably 

will be displayed. Use the START 

button to set which of the 5 operating modes you want (see 
below for a description of each.) After you have selected the 
mode you want then press the 

STOP 

button. The display will 

blank momentarily to indicate that programming mode has 
ended and the 4 digits you set to count down from will be 
displayed. For example, 

27.30 

if you want to count down from 

27 minutes 30 seconds. The timer is now programmed ready 
to go. 

 

 
STARTING THE TIMER 

Press the 

START 

button or apply a ground to the start input 

and the timer will start counting down towards zero. The 
STOP button or input has no affect while the timer is 
counting down. 

 

Accuracy

. Timing will be accurate to /- 1.8 sec per 

hour (3600 seconds.) 

 

 
STOPPING THE TIMER 

The only way to stop the timer is via the reset input. Short 
the Reset pin to ground. The timer will reset to its 
programmed value and the operating mode is not affected. If 
the timer loses power it will restart in Mode 1 with a preset 
value of 

00.00 

(100 minutes). 

 

 

OPERATING MODES 

There are five operating modes that control the timer and the 
output. The RESET input does not affect the operating mode. 

 

Mode 1. Timer Stop, Output Hold (default) 

This is the default mode at power up. The timer stops when 
it reaches zero and the Output goes low and stays low. You 
have to press Reset (short the Reset pin to ground) to 
continue. 

 

Mode 2. Timer Overrun, Output Hold 

Same as Mode 1 except the timer continues counting down 
past zero, wraps around to 99.59 and starts counting down 
from there. The Output pin goes low and stays low. Short the 
Reset pin to ground to return to the preset timer value. 

 

Mode 3. Auto Reset, Pulse Output 

When the timer reaches zero the Output pulses low for 20mS 
and the timer resets itself to the programmed value and 
stays there. You can start to count down again from the 
preset value by pressing START. 

 

Mode 4. Timer Overrun, Pulse Output 

Same  as  Mode  2  except  the  output  pulses  low  for  20msec 
instead  of  staying  low.  Counting  wraps  to  99.59  and  starts 
counting  down.  Short  the  Reset  pin  to  ground  to  return  to 
the preset timer value. 
 

Mode 5. Output On, Timer Run 