background image

NOVUS AUTOMATION 

1/2 

 

 

 

TIMER TM-619 

PROGRAMMABLE TIME INTERRUPTERS - USER GUIDE V4.0x D

 

1. OPERATING FEATURE 

The Programmable Time Interrupters NOVUS are electronic devices 

that permit  switching  electrical  loads  (alarm,  appliances,  etc.) at 

programmed time intervals with good accuracy.  
Their  microprocessor let you create at most eight (8) ON/OFF 

programs, which can switch  electrical loads at specifics moments 

throughout the week.    
They have a battery, that give to the TIMER the feature of hold the 

programs and run the internal clock for many weeks, even in case of 

power outage. 
The output is consist of a relay with the terminals NO, COM and NC 

(SPDT) available for user. In power outage this relay will not switch, 

letting the output inoperative.   

2. SPECIFICATIONS 

 

POWER: de 12 Vdc, 24 Vdc, 110 Vac or 240 Vac, 50/60 Hz; (see 

identification tag); no polarity of the terminals. 

 

Switching low interval: 1 minute; 

 

OUTPUT: Relay 16 A / 250 Vac, resistive; 8 A / 250 Vac, inductive; 

 

Operational temperature: 0 to 60 °C; 

 

Storage temperature: -10 to 75 °C; 

 

Light indicator for output on (when powered); 

 

Proper for be fixed with screw. 

3. OPERATIONS MODES 

There are three operation modes: ONAUTO e OFF, select through 

the MANUAL key. When the MANUAL key is pressed, observe that 

the  indicator (line)  on the screen move upon the words 

ON/AUTO/OFF: 

 

MODO ON: When the indicator is upon ON the output turn on 

immediately and keep this status while in ON mode. 

 

 MODO OFF: When the indicator is upon OFF the output turn off 

immediately and keep this status while in OFF mode. 

 

MODO AUTO: When the indicator is upon AUTO the output turn 

on and turn off based on the programs. 

When the TIMER isn’t powered, it turns off the output permanently. 

4. UPDATING DAY/HOUR/MINUTE 

Keep pressed the CLOCK key, then press: 

 

DAY:  to update the indicated day of week; 

 

HOUR:  to update the indicated hour; 

 

MIN:   to update the indicated minutes. 

NOTE 1: The terms MO, TU, WE, TH, FR, SA e SU, correspond to 

the weekdays in English: 
MO= Monday;   

TU= Tuesday;  WE= Wednesday; 

TH= Thursday;   

FR= Friday;    SA=Saturday; 

SU= Sunday; 

5. DETERMINING THE ON/OFF CYCLES  

Press the TIMER  key to access and configure the  ON/OFF 

programs. The program number, which is at editing, is showed on the 

left  side  of the  screen. See Fig.  04. The first edit refers to the 

program 1 and determine the moment to turn on the output. Note that 

the message ON is showed upon the program number.  

 

Press DAY to determine the day which the output should turn on. 

Observe that the indication of the weekdays is changed at each 

time that DAY key is pressed: 

 

MoTuWeThFrSaSu (everyday) 

 

Mo (any day of the week); 

 

Tu (Tuesday); 

 

We (Wednesday); 

 

Th (Thursday); 

 

Fr (Friday); 

 

Sa (Saturday); 

 

Su (Sunday); 

 

MoTuWeThFr (business days); 

 

SaSu (weekend); 

 

MoTuWeThFrSa (business days more Saturday); 

 

MoTuWe (Monday, Tuesday and Wednesday); 

 

ThFrSa (Thursday, Friday and Saturday); 

 

MoWeFr (Monday, Wednesday and Friday); 

 

TuThSa (Tuesday, Thursday and Saturday); 

 

Press the HOUR key to determine the hour on the chosen days, 

in which the output turns on.  

 

Press the MIN key to determine the minutes. 

Press the TIMER key again to determine the moment to turn off the 

output on the program 1. Note that the message OFF  upon the 

program number. The programming of day, hour and minute is made 

identical of the programming of turn ON, showed before: 

 

Press DAY key to determine the days when the output is turned 

off. 

 

Press the HOUR key to determine the hour when the output turns 

off.  

 

Press the MIN key to determine the minutes. 

Press the TIMER key again and the program number displayed will 

change to 2, indicating that the following adjusts refer to program 2. 

Configure the program 2 as the instruction above. Then access and 

determine the other programs, in a total eight programs.  
These programs  will be used by the TIMER when the operation 

mode selected is AUTO. In the time programmed to ON, the output 

turns on. In the time programmed to OFF, the output turns off.  
In the case of overlapping programs, the output will act like the 

example showed at the Fig. 01. When it’s already on, and came a 

time when some program turn off, the output turn off. When came a 

time in some program when turn on, the output doesn’t change.  