LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING

z

0.46" (11.7 mm) HIGH DIGITS

z

7-DIGIT BI-DIRECTIONAL TIMING CAPABILITY

z

6-DIGIT CYCLE COUNTING CAPABILITY

z

OPTIONAL RELAY OUTPUT MODULE

z

OPTIONAL SERIAL COMMUNICATIONS MODULE (RS232 or RS485)

z

SELECTABLE TIMER RANGES AND OPERATING MODES

z

ELAPSED TIMER AND PRESET TIMER FUNCTIONALITY

z

DISPLAY COLOR CHANGE CAPABILITY AT PRESET OUTPUT

z

OPERATES FROM 9 TO 28 VDC POWER SOURCE

z

NEMA 4X/IP65 SEALED FRONT BEZEL

MODEL CUB5T - MINIATURE ELECTRONIC PRESET TIMER 

AND CYCLE COUNTER

GENERAL DESCRIPTION

The CUB5T provides the ultimate in timer flexibility, from its complete user

programming to the optional relay output and serial communications capability.
The meter functions as an Elapsed Timer or Preset Timer. It also has a built-in
Cycle Counter. The display can be toggled either manually or automatically
between the Timer and Cycle Counter values. With eight different input
operating modes and 18 selectable timer ranges, the meter can be programmed
for a wide variety of timing applications.

The CUB5T has an LCD display with 0.46" (11.7 mm) high digits. The LCD

is available in two versions, reflective (CUB5TR00) and backlight
(CUB5TB00). The backlight version is user selectable for red or green
backlighting with variable display intensity.

The Timer has two signal inputs and eight input operating modes. These

modes provide level active or edge triggered start/stop operation. A Display
Hold mode will display the elapsed time for one cycle, while the next cycle
continues timing internally. The Timer Reset modes will automatically reset the
timer value when a time start edge is applied to the input. This allows sequential
timing cycles without having to manually reset the Timer.

In addition to the Timer inputs, a programmable User Input is available to

perform a variety of meter functions. All inputs are current sinking (active low)
and accept a variety of logic and open-collector output signal sources. Relay and
switch contacts can also be used as signal sources, when the software input
debounce filter is enabled.

The capability of the CUB5T can be easily expanded with the addition of a

field installable option module. When the CUB5RLY0 relay output module is
added, the meter becomes a Preset Timer. The Setpoint Output can be assigned
to the Timer or Cycle Counter values, and configured to suit a variety of control
and alarm requirements. Serial communications capability for RS232 or RS485
is added with a serial option module (CUB5COM).

The CUB5T can be powered from an optional Red Lion Micro-Line/Sensor

Power Supply (MLPS1000), which attaches directly to the back of a CUB5T.
The MLPS1 is powered from an 85 to 250 VAC source and provides up to 400
mA to drive the meter and sensors.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use this meter to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the meter.

Bulletin No.  CUB5T-X
Drawing No.  LP0628
Effective  11/05

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.

Summary of Contents for CUB5T

Page 1: ...to the Timer inputs a programmable User Input is available to perform a variety of meter functions All inputs are current sinking active low and accept a variety of logic and open collector output sig...

Page 2: ...re Range for CUB5TR00 35 to 75 C Operating Temperature Range for CUB5TB00 depends on display color and intensity level as per below Storage Temperature 35 to 85 C Operating and Storage Humidity 0 to 8...

Page 3: ...ed to be mounted into an enclosed panel Prepare the panel cutout to the dimensions shown Remove the panel latch from the unit Slide the panel gasket over the rear of the unit to the back of the bezel...

Page 4: ...lly useful in applications where cable runs are long and portable two way radios are used in close proximity or if the installation is near a commercial radio transmitter 4 Signal or Control cables wi...

Page 5: ...must be suitably isolated from hazardous live earth referenced voltage or input common must be at protective earth ground potential If not hazardous voltage may be present at the User Inputs and User...

Page 6: ...is exited by pressing the SEL key with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Di...

Page 7: ...S HHHHH NN 99999 59 1 MIN NNN SS SS 999 59 99 0 01 SEC NNNNN SS 99999 59 1 SEC NNNN SS S 9999 59 9 0 1 SEC MAXIMUM DISPLAY DISPLAY RESOLUTION RANGE SELECTION MINUTES SECONDS LEVsrSt LEVEL Ed 1srSt Ed9...

Page 8: ...pplications but can also provide an offset value when counting up UP dn 000000 to 999999 USER INPUT ASSIGNMENT The User Input Assignment only applies if the cycle counter is enabled and a selection of...

Page 9: ...be modified but allows direct access to these values without having to enter Full Programming mode Programming a Security Code other than 0 requires this code to be entered at the Pro CodE prompt in...

Page 10: ...if the output should not cause a display reset TIMER COUNTER AUTO RESET Select YES to have the Setpoint Output deactivate reset when the Setpoint Assigned display resets Reset can occur by the RST bu...

Page 11: ...h meter The node address applies specifically to RS485 applications This parameter determines the formatting of data transmitted from the meter in response to a Transmit Value command or a Block Print...

Page 12: ...t Time out Setpoint OFF STO SOF 6 digit mm ss ss format per Setpoint Assignment same as Timer or Counter T V R T V R T V T V T V T V R T V T V Receiving Data From The Meter Data is transmitted from th...

Page 13: ...unication channel In serial communications the voltage is switched between a high and low level at a predetermined rate baud rate using ASCII encoding The receiving device reads the voltage levels at...

Page 14: ...14 This page intentionally left blank...

Page 15: ...15 CUB5T PROGRAMMING QUICK OVERVIEW Press and hold SEL key to enter Programming Mode...

Page 16: ...based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalti...

Reviews: