background image

15

CUB5T PROGRAMMING QUICK OVERVIEW

Press and hold 

SEL

key to

enter Programming

Mode.

Summary of Contents for CUB5T

Page 1: ...to the Timer inputs a programmable User Input is available to perform a variety of meter functions All inputs are current sinking active low and accept a variety of logic and open collector output sig...

Page 2: ...re Range for CUB5TR00 35 to 75 C Operating Temperature Range for CUB5TB00 depends on display color and intensity level as per below Storage Temperature 35 to 85 C Operating and Storage Humidity 0 to 8...

Page 3: ...ed to be mounted into an enclosed panel Prepare the panel cutout to the dimensions shown Remove the panel latch from the unit Slide the panel gasket over the rear of the unit to the back of the bezel...

Page 4: ...lly useful in applications where cable runs are long and portable two way radios are used in close proximity or if the installation is near a commercial radio transmitter 4 Signal or Control cables wi...

Page 5: ...must be suitably isolated from hazardous live earth referenced voltage or input common must be at protective earth ground potential If not hazardous voltage may be present at the User Inputs and User...

Page 6: ...is exited by pressing the SEL key with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Di...

Page 7: ...S HHHHH NN 99999 59 1 MIN NNN SS SS 999 59 99 0 01 SEC NNNNN SS 99999 59 1 SEC NNNN SS S 9999 59 9 0 1 SEC MAXIMUM DISPLAY DISPLAY RESOLUTION RANGE SELECTION MINUTES SECONDS LEVsrSt LEVEL Ed 1srSt Ed9...

Page 8: ...pplications but can also provide an offset value when counting up UP dn 000000 to 999999 USER INPUT ASSIGNMENT The User Input Assignment only applies if the cycle counter is enabled and a selection of...

Page 9: ...be modified but allows direct access to these values without having to enter Full Programming mode Programming a Security Code other than 0 requires this code to be entered at the Pro CodE prompt in...

Page 10: ...if the output should not cause a display reset TIMER COUNTER AUTO RESET Select YES to have the Setpoint Output deactivate reset when the Setpoint Assigned display resets Reset can occur by the RST bu...

Page 11: ...h meter The node address applies specifically to RS485 applications This parameter determines the formatting of data transmitted from the meter in response to a Transmit Value command or a Block Print...

Page 12: ...t Time out Setpoint OFF STO SOF 6 digit mm ss ss format per Setpoint Assignment same as Timer or Counter T V R T V R T V T V T V T V R T V T V Receiving Data From The Meter Data is transmitted from th...

Page 13: ...unication channel In serial communications the voltage is switched between a high and low level at a predetermined rate baud rate using ASCII encoding The receiving device reads the voltage levels at...

Page 14: ...14 This page intentionally left blank...

Page 15: ...15 CUB5T PROGRAMMING QUICK OVERVIEW Press and hold SEL key to enter Programming Mode...

Page 16: ...based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalti...