background image

Copyright © 1997, Tjernlund Products, Inc.  All rights reserved.

P/N 8504067

REV.  10/97

READ INSTRUCTIONS CAREFULLY

RELAY/TIMER PART NUMBER 950-0014

24/24 VAC NON-ADJUSTABLE RELAY/TIMER

OWNERS INSTRUCTIONS

THESE INSTRUCTIONS MUST REMAIN

WITH EQUIPMENT

DO NOT DESTROY

ALWAYS FOLLOW HEATER

MANUFACTURER’S INSTRUCTION

FOR PROPER OPERATION OF

HEATER AND RELIGHTING OF PILOT

PART #950-0014 INSTALLATION INSTRUCTIONS

24/24 VAC INPUT APPROX. 45 SECOND

NON-ADJUSTABLE POST-PURGE RELAY/TIMER                                                               

A) Disconnect 115 VAC Power from the Power Venter before continuing.

B) All wiring from the Power Venter to the appliance must be appropriate class 1 wiring as follows: installed in rigid-metal conduit, 

intermediate metal conduit, rigid non-metallic conduit, electrical metallic tubing, Type MI Cable, Type MC Cable or be otherwise 
suitably protected from physical damage.

REPLACEMENT OF DEFECTIVE RELAY/TIMER

1. Remove the electrical box cover of the Power Venter.

2. Place the replacement Timer next to the defective Timer located in the Power Venter electrical box.

3. One by one, remove the wires from the defective Timer and connect them to the corresponding number on the replacement Timer. 

4. Remove the defective Timer from the electrical box by pulling Timer up and off of mounting tabs.

5. Position new Timer over the 4 mounting studs and push down onto mounting tabs until Timer is secured into place.

6. If the defective Timer failed within the 1 year warranty period, you may return it along with proof of purchase to the Tjernlund 

Distributor it was originally purchased from for a full refund.

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

Reviews: