background image

 

«NOVATEK-ELECTRO» LTD 

   Intelligent Industrial Electronics 

 

 

 

 

 

 

PUMPING PLANT  
CONTROLLER 

 

MCK-108 

 
 

 

 
 
 
 

OPERATING MANUAL 

 
 

 

Quality control system on the development and production complies with requirements ISO 9001:2015 

 

 

 

Dear customer, 

Company NOVATEK-ELECTRO LTD. thanks you for purchasing our products. 

You will be able to use properly the product after carefully studying the Operating Manual.  

Keep the Operating Manual throughout the service life of the product. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

UKRAINE, Odessa

 

 

 

          

     

 

 

www.novatek-electro.com 

 

Summary of Contents for MCK-108

Page 1: ...pment and production complies with requirements ISO 9001 2015 Dear customer Company NOVATEK ELECTRO LTD thanks you for purchasing our products You will be able to use properly the product after carefu...

Page 2: ...UT DISCONNECTING THE PRODUCT FROM THE MAINS TO OPEN AND REPAIR THE PRODUCT INDEPENDENTLY TO OPERATE THE PRODUCT WITH MECHANICAL DAMAGES OF THE CASE IT IS NOT ALLOWED WATER PENETRATION ON TERMINALS AND...

Page 3: ...g the tear and wear the user can set the alternate operation of the pumps To prevent failure of the electric motor while draining the well one may use a dry run sensor conduction measuring dry run sen...

Page 4: ...lling mode it glows red while in the drainage mode it blinks green 13 LED UL Upper Level glows red if the liquid level is higher than the upper level sensor 14 LED EL Emergency Level glows red if the...

Page 5: ...o standard 35 mm DIN rail The device preserves functionality in any position within the space Casing material self extinguishing plastic Table 3 The characteristics of the integrated relays output con...

Page 6: ...ure of the terminal block screws or the compression of the connected wire To increase the running ability of MCK 108 it is recommended to install protection devices fuse links or their equivalents int...

Page 7: ...ng in the filling mode with the pressure sensor turn the switch CPG S L CPG Level Sensor to CPG position and turn the switch Drn Fi Drainage Filling to Fi position 3 1 9 By using the handle hs adjust...

Page 8: ...EL liquid level is lower than DR failure of UL LL or DR sensors 1 submersible pump 2 MCK 108 3 dry run sensor electrode 4 electrodes EL emergency level UL upper level LL lower level Com common Figure...

Page 9: ...repeated 3 2 1 4 Operation in the automated drainage mode with the level sensors In the initial state in case the liquid level in the tank is lower than the UL sensor when starting the power supply t...

Page 10: ...s is allowed the LED EL goes out the functional relay deactivates the alarm If the EL sensor is off the LED EL goes out 3 2 3 3 Failures of the pressure level sensors are specified in Table 4 Table 4...

Page 11: ...rer at current rates 5 6 Before sending for repair the product should be packed in the original or other packing excluding mechanical damage Earnest request indicate the reason for return in the notic...

Reviews: