Table 6. Abbreviated list of POST error messages
POST message
Failing device or problem found
Suggested action
161
The real-time clock battery has
failed.
Replace the battery.
162
A device configuration has
changed.
Make sure that your optional devices are turned on
and installed correctly.
✏
NOTE
If you are unable to start the
Configuration/Setup Utility program, view the
system event log in the management module.
163
The time of day has not been set.
Set the correct date and time.
289
A failing DIMM was disabled.
Make sure that the memory is correct for your
NovaScale Blade Server and that it is installed
properly.
301
303
Keyboard and keyboard controller
•
Make sure that the keyboard/mouse/video select
button LED on the front of the NovaScale Blade
Server is lit, indicating that the NovaScale Blade
Server is connected to the shared keyboard.
•
Make sure that the keyboard cable is connected
to the NovaScale Blade Chassis unit and nothing
is resting on the keyboard keys.
962
Parallel port configuration error
Start the Configuration/Setup Utility program and
make sure that the parallel-port setting is correct.
11
xx
Serial port error
Make sure that the serial cable is connected correctly.
1162
Serial port configuration conflict
Start the Configuration/Setup Utility program and
make sure that the IRQ and I/O port assignments
needed by the serial port are available.
1800
PCI adapter hardware interrupt
Start the Configuration/Setup Utility program and
make sure that the interrupt resource settings are
correct.
2400
2462
Video controller and memory
•
Make sure that the keyboard/mouse/video select
button LED on the front of the NovaScale Blade
Server is lit, indicating that the NovaScale Blade
Server is connected to the shared monitor.
•
Make sure that the monitor is connected correctly
to the NovaScale Blade Chassis unit.
00019
xxx
Processor
x
is not functioning or
failed the built-in test.
Make sure that processor
x
is installed correctly. If the
problem remains, replace processor
x
.
Summary of Contents for Blade 2021 Series
Page 2: ......
Page 16: ...xiv NovaScale Blade 2021 Installation and User s Guide This page intentionally left blank...
Page 28: ...10 NovaScale Blade 2021 Installation and User s Guide...
Page 66: ...48 NovaScale Blade 2021 Installation and User s Guide...
Page 76: ...58 NovaScale Blade 2021 Installation and User s Guide...
Page 88: ...70 NovaScale Blade 2021 Installation and User s Guide...
Page 90: ...72 NovaScale Blade 2021 Installation and User s Guide...
Page 97: ......
Page 98: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 96EM 00 REFERENCE...